Evaluationsstudie in der Zeitschrift Journal of Clinical Monitoring and Computing, 2024. Verfasst von Ramsés Marrero-García und 4 weiteren Autor:innen. Beteiligte Einrichtung: Critical Care Department and Pain Unit, Clinic Hospital, Barcelona, Spain. ramsesmg1992@gmail.com. Hauptthemen laut MEDLINE: Oximetry, Ischemia, Muscle, Skeletal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The main objective of this study is to evaluate the low-cost, open-source HEGduino device as a tissue oximetry monitor to advance the research of somatic NIRS monitoring. Specifically, this study analyzes the use of this portable functional NIRS system for detecting the cessation of blood flow due to vascular occlusion in an upper limb. 19 healthy patients aged between 25 and 50 were recruited and monitored using HEGduino device. Participants underwent a vascular occlusion test on one forearm. Raw values collected by HEGduino as well as the processed variables derived from the measurements were registered. Additional variables to characterize the signal noise during the tests were also recorded. The results of the data distribution curves for all the subjects in the study accurately detected the physiological events associated with transient tissue ischemia. The statistical analysis of the recorded data showed that the difference between the baseline values recorded by the red led (RED) and its normalized minimum variable was always different from zero (p < 0.014). Furthermore, the difference between the normalized baseline values recorded by the infrared led (IR) and the corresponding normalized minimum value was also different from zero (p < 0.001). The R-squared coefficient of determination for the noise variables considered in this study on the normalized RED and IR values was 0.08 and 0.105, respectively. The study confirms the potential of HEGduino system to detect an interruption of the blood flow by means of variations in regional tissue oxygen saturation. This study demonstrates the potential of the HEGduino device as a monitoring alternative to advance the study of the applicability of NIRS in muscle tissue oximetry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OximetryIschemiaMuscle, SkeletalHumansSpectroscopy, Near-InfraredAdultMaleMiddle AgedFemaleMonitoring, PhysiologicForearmSignal-To-Noise RatioEquipment DesignSignal Processing, Computer-AssistedReproducibility of ResultsOxygenRegional Blood FlowOxygen Saturation

Stichwörter der Autor:innen

HEGduinoLow-cost deviceNIRSOpen-source hardwareSomatic NIRS monitoring

Substanzen

Oxygen

Autor:innen und Institutionen

  • Critical Care Department and Pain Unit, Clinic Hospital, Barcelona, Spain. ramsesmg1992@gmail.com.
  • Anesthesia, Resuscitation and Pain Unit, Cruces Hospital, 48903, Baracaldo, Spain.
  • Departamento de Ingeniería Informática y de Sistemas, Universidad de La Laguna, Camino San Francisco de Paula, 19, La Laguna, 38200, Canary Islands, Spain.
  • Hospital Universitario de Canarias, Ctra. Ofra s/n, La Laguna, 38320, Canary Islands, Spain.

Zitieren

APA

Marrero-García, R., Cruz-Tabares, Y., Gonzalez-Cava, J. M., Méndez-Pérez, J. A., & Reboso-Morales, J. A. (2024). Evaluation of a low-cost portable NIRS device for monitoring muscle ischemia. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01226-2

Vancouver

Marrero-García R, Cruz-Tabares Y, Gonzalez-Cava JM, Méndez-Pérez JA, Reboso-Morales JA. Evaluation of a low-cost portable NIRS device for monitoring muscle ischemia. Journal of Clinical Monitoring and Computing. 2024. doi:10.1007/s10877-024-01226-2

BibTeX
@article{MarreroGarca2024,
  author = {Marrero-García, Ramsés and Cruz-Tabares, Yaiza and Gonzalez-Cava, Jose M and Méndez-Pérez, Juan Albino and Reboso-Morales, José Antonio},
  title = {Evaluation of a low-cost portable NIRS device for monitoring muscle ischemia},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2024},
  doi = {10.1007/s10877-024-01226-2}
}
Kostenlos starten →