Combined sonographic optic nerve sheath diameter and cerebral oximeter for predicting neurological outcome after cardiac arrest
Biomolecules and Biomedicine · 2024
DOI: 10.17305/bb.2024.11442 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomolecules and Biomedicine, 2024. Verfasst von Mehmet Akif Yazar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Outcome Research Consortium, Cleveland Clinic, Cleveland, OH, USA; University of Health Sciences, Konya City Hospital, Department of Anesthesiology a…. Hauptthemen laut MEDLINE: Optic Nerve, Heart Arrest, Oximetry. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Reanimation
Abstract (Originalsprache)
Cardiac arrest (CA) remains a critical global health issue with high rates of mortality and morbidity. Accurate prediction of neurological outcomes in post-CA patients is essential for optimizing management strategies. Optic nerve sheath diameter (ONSD) and near-infrared spectroscopy (NIRS) are emerging as promising tools for evaluating brain oxygenation and intracranial pressure. However, the potential benefits of combining these methods for improved prognostic accuracy have not been thoroughly explored. This study investigates whether the combined use of ultrasonographic ONSD and NIRS measurements enhances the prediction of neurological outcomes after CA. In this prospective study, ONSD measurements were obtained three times at 24-hour intervals, while regional hemoglobin oxygen saturation (rSO2) using NIRS was recorded twice. Neurological outcomes were assessed using the Full Outline of Unresponsiveness (FOUR) and Cerebral Performance Categories (CPC) scores for both early and late evaluations. Results indicated that 47.5% of patients had poor outcomes and 52.5% had good outcomes based on the FOUR score, while 65% had poor outcomes and 35% had good outcomes according to the CPC score. The combination of ONSD and NIRS measurements showed superior prognostic performance compared to either method alone. While standalone NIRS measurements taken after 24 hours exhibited limited predictive value, combining ONSD and NIRS provided a more reliable approach for neurological assessment in the short term following CA. This integrated method may improve prognostic accuracy and support better clinical decision-making.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Outcome Research Consortium, Cleveland Clinic, Cleveland, OH, USA; University of Health Sciences, Konya City Hospital, Department of Anesthesiology and Reanimation, Konya, Türkiye.
- University of Health Sciences, Konya City Hospital, Department of Anesthesiology and Reanimation, Konya, Türkiye.
- University of Health Sciences, Konya City Hospital, Department of Radiology, Konya, Türkiye.
Zitieren
APA
Yazar, M. A., Kozanhan, B., Tire, Y., Sekmenli, N., Yazar, G., & Sevim, M. (2024). Combined sonographic optic nerve sheath diameter and cerebral oximeter for predicting neurological outcome after cardiac arrest. Biomolecules and Biomedicine. https://doi.org/10.17305/bb.2024.11442
Vancouver
Yazar MA, Kozanhan B, Tire Y, Sekmenli N, Yazar G, Sevim M. Combined sonographic optic nerve sheath diameter and cerebral oximeter for predicting neurological outcome after cardiac arrest. Biomolecules and Biomedicine. 2024. doi:10.17305/bb.2024.11442
BibTeX
@article{Yazar2024,
author = {Yazar, Mehmet Akif and Kozanhan, Betul and Tire, Yasin and Sekmenli, Nevin and Yazar, Guzide and Sevim, Murat},
title = {Combined sonographic optic nerve sheath diameter and cerebral oximeter for predicting neurological outcome after cardiac arrest},
journal = {Biomolecules and Biomedicine},
year = {2024},
doi = {10.17305/bb.2024.11442}
}
EUVIMED