EUVIMEDEUVIMED entdecken
EditorialOpen Access · CC BY 4.0

Towards the automatic detection and correction of abnormal arterial pressure waveforms

Frederic Michard

Journal of Clinical Monitoring and Computing · 2024-08 · 38 (4) · 749-752

DOI: 10.1007/s10877-024-01152-3 ↗

Kurz gefasst

Editorial in der Zeitschrift Journal of Clinical Monitoring and Computing, online erschienen am 04.04.2024. Verfasst von Frederic Michard. Beteiligte Einrichtung: MiCo, Vallamand, Switzerland. frederic.michard@bluewin.ch. Hauptthemen laut MEDLINE: Algorithms, Arterial Pressure, Blood Pressure Determination, Pulse Wave Analysis. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Both over and underdamping of the arterial pressure waveform are frequent during continuous invasive radial pressure monitoring. They may influence systolic blood pressure measurements and the accuracy of cardiac output monitoring with pulse wave analysis techniques. It is therefore recommended to regularly perform fast flush tests to unmask abnormal damping. Smart algorithms have recently been developed for the automatic detection of abnormal damping. In case of overdamping, air bubbles, kinking, and partial obstruction of the arterial catheter should be suspected and eliminated. In the case of underdamping, resonance filters may be necessary to normalize the arterial pressure waveform and ensure accurate hemodynamic measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsArterial PressureBlood Pressure DeterminationPulse Wave AnalysisHumansCardiac OutputSignal Processing, Computer-AssistedAutomationMonitoring, PhysiologicReproducibility of ResultsHemodynamicsBlood Pressure

Stichwörter der Autor:innen

Arterial pressure monitoringCardiac outputDampingResonanceSystolic pressure

Autor:innen und Institutionen

  • MiCo, Vallamand, Switzerland. frederic.michard@bluewin.ch.

Zitieren

APA

Michard, F. (2024). Towards the automatic detection and correction of abnormal arterial pressure waveforms. Journal of Clinical Monitoring and Computing, 38(4), 749-752. https://doi.org/10.1007/s10877-024-01152-3

Vancouver

Michard F. Towards the automatic detection and correction of abnormal arterial pressure waveforms. Journal of Clinical Monitoring and Computing. 2024;38(4):749-752. doi:10.1007/s10877-024-01152-3

BibTeX
@article{Michard2024,
  author = {Michard, Frederic},
  title = {Towards the automatic detection and correction of abnormal arterial pressure waveforms},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2024},
  volume = {38},
  number = {4},
  pages = {749--752},
  doi = {10.1007/s10877-024-01152-3}
}
Kostenlos starten →