EUVIMEDEUVIMED entdecken
Crossref

Effect of tidal volume change on pressure‐based prediction of fluid responsiveness in children

Sang-Hwan Ji iD, Young-Eun Jang iD, Jung-Bin Park iD, Pyoyoon Kang iD, Sung-Ae Cho iD, Eun-Hee Kim iD, Ji-Hyun Lee iD, Hee-Soo Kim iD, Jin-Tae Kim iD

Pediatric Anesthesia · 2023

DOI: 10.1111/pan.14751 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Anesthesia, 2023. Verfasst von Sang-Hwan Ji und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Fluid Therapy, Hemodynamics. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

It is known that pulse pressure variation and systolic pressure variation cannot predict fluid responsiveness in children. In adults, the ability of these dynamic parameters to predict fluid responsiveness is improved by increasing tidal volume. We planned to investigate whether pulse pressure variation or systolic pressure variation can predict fluid responsiveness in children when augmented by increasing tidal volume by conducting a prospective study.

Methods

We enrolled children younger than 7 years who underwent cardiac surgery for atrial septal defect or ventricular septal defect. After sternum closure, pulse pressure variation and systolic pressure variation were continuously recorded while changing the tidal volume to 6, 10, and 14 mL/kg. Fluid loading was done with 10 mL/kg of crystalloids for 10 min, and stroke volume index was measured via transesophageal echocardiography. Children whose stroke volume index increased by more than 15% after the fluid loading were defined as responders to fluid therapy. We set primary outcome as the predictability of pulse pressure variation and systolic pressure variation for fluid responsiveness and measured the area under the curve of receiver operating characteristics curve.

Results

Twenty‐six children were included, of which 15 were responders. At the tidal volume of 14 mL/kg, the area under the curves of receiver operating characteristics curves of pulse pressure variation and systolic pressure variation were 0.576 ( p = .517) and 0.548 ( p = .678), respectively. The differences in dynamic parameters between responders and nonresponders were not significant.

Discussion

Failure of pulse pressure variation or systolic pressure variation at augmented tidal volume in children may be due to difference in their arterial compliance from those of adults. Large compliance of thoracic wall may be another reason.

Conclusions

Augmented pulse pressure variation or systolic pressure variation due to increased tidal volume cannot predict fluid responsiveness in children after simple cardiac surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluid TherapyHemodynamicsAdultHumansChildProspective StudiesTidal VolumeBlood PressureStroke VolumeHeart RateROC CurveRespiration, Artificial

Stichwörter der Autor:innen

childfluid therapythoracic surgerytidal volume

Autor:innen und Institutionen

  • Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
  • Department of Anesthesiology and Pain Medicine, Konyang University Hospital, Konyang University College of Medicine Daejeon, Daejeon, Korea.

ORCID-Profile: Sang-Hwan Ji, Young-Eun Jang, Jung-Bin Park, Pyoyoon Kang, Sung-Ae Cho, Eun-Hee Kim, Ji-Hyun Lee, Hee-Soo Kim, Jin-Tae Kim

Zitieren

APA

Ji, S. H., Jang, Y. E., Park, J. B., Kang, P., Cho, S. A., Kim, E. H., Lee, J. H., Kim, H. S., & Kim, J. T. (2023). Effect of tidal volume change on pressure‐based prediction of fluid responsiveness in children. Pediatric Anesthesia. https://doi.org/10.1111/pan.14751

Vancouver

Ji SH, Jang YE, Park JB, Kang P, Cho SA, Kim EH, et al. Effect of tidal volume change on pressure‐based prediction of fluid responsiveness in children. Pediatric Anesthesia. 2023. doi:10.1111/pan.14751

BibTeX
@article{Ji2023,
  author = {Ji, Sang-Hwan and Jang, Young-Eun and Park, Jung-Bin and Kang, Pyoyoon and Cho, Sung-Ae and Kim, Eun-Hee and Lee, Ji-Hyun and Kim, Hee-Soo and Kim, Jin-Tae},
  title = {Effect of tidal volume change on pressure‐based prediction of fluid responsiveness in children},
  journal = {Pediatric Anesthesia},
  year = {2023},
  doi = {10.1111/pan.14751}
}
Kostenlos starten →