EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieOpen Access · CC BY-NC-ND 4.0

From trial to practice: early multicenter real-world experience with the circular pulsed field ablation catheter

Gabriel Ballesteros, Alberto Barrera, Nicasio Pérez Castellano, Francisco Mazuelos Bellido, Leopoldo Fernández-Ruz, Germán Bertelli, David Calvo Cuervo, Guillermo Gutiérrez Ballesteros, Jaime González-Lozano, Javier Muñiz, Alba Cruz Galbán, Amalio Ruiz und 2 weitere

Journal of Interventional Cardiac Electrophysiology · 31.07.2026 · 69 (9) · 2939-2951

DOI: 10.1007/s10840-026-02410-x ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 31.07.2026. Verfasst von Gabriel Ballesteros und 13 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Regional Universitario de Málaga, Avenida Carlos Haya, 36, Málaga, 29010, Spain. drballesteroscardiologia@gmail.com. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Postoperative Complications. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The PulseSelect™ circular pulsed field ablation (PFA) catheter demonstrated excellent safety in its pivotal trial, but real-world evidence on its early adoption and implementation remains scarce.

Objective

To report the first multicentre, real-world experience of atrial fibrillation (AF) ablation with the PulseSelect circular PFA catheter, focusing on procedural characteristics, metrics, safety and short-term clinical outcomes.

Methods

This observational study included the first 520 consecutive patients undergoing AF ablation with the PulseSelect catheter across five Spanish centres. Patient and procedural characteristics, safety (major complications), acute pulmonary vein isolation (PVI) rate and arrhythmia recurrence during follow-up were recorded.

Results

Acute PVI was achieved in 518/520 patients (99.6%). Procedures were performed under deep sedation (52.7%) or general anaesthesia (47.3%), without anaesthesia-related complications. Mean procedural time was 69.95 min, with a learning curve plateauing after the first 8–10 cases. Same-day or < 24 h discharge occurred in 95.4%. Major complications occurred in four patients (0.76%); no deaths or clinically evident haemolysis were observed. Electroanatomical mapping (EAM) was used in a minority of cases (3.65%); when used, there was 100% concordance between post-ablation maps and PulseSelect catheter recordings in confirming PVI. During a mean follow-up of 10.8 ± 5 months, arrhythmia recurrence after the 3-month blanking period occurred in 16.2% of patients. After one year of follow-up, arrhythmic recurrence was observed in 52/220 (23.63%) patients.

Conclusions

In the first large real-world series, AF ablation with the PulseSelect circular PFA catheter without routine use of EAM was feasible, safe, and effective, with major complications < 1% and short hospitalisation. These findings support rapid and safe implementation of this technology in clinical practice, with flexibility regarding anaesthesia modality. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationPostoperative ComplicationsHumansFemaleMaleTreatment OutcomeMiddle AgedSpainIrreversible Electroporation TherapyPulmonary VeinsAgedEquipment DesignRisk FactorsPrevalenceEquipment Failure Analysis

Autor:innen und Institutionen

  • Hospital Regional Universitario de Málaga, Avenida Carlos Haya, 36, Málaga, 29010, Spain. drballesteroscardiologia@gmail.com.
  • Hospital Universitario HLA El Ángel, Málaga, Spain. drballesteroscardiologia@gmail.com.
  • Hospital Universitario Virgen de la Victoria, Málaga, Spain.
  • Hospital Clínico San Carlos, CIBERCV, Madrid, Spain.
  • Instituto de Ciencias Médicas Córdoba, Hospital Universitario Reina Sofía, IMIBIC, Córdoba, Spain.
  • Hospital Regional Universitario de Málaga, Avenida Carlos Haya, 36, Málaga, 29010, Spain.

Zitieren

APA

Ballesteros, G., Barrera, A., Pérez Castellano, N., Mazuelos Bellido, F., Fernández-Ruz, L., Bertelli, G., Calvo Cuervo, D., Gutiérrez Ballesteros, G., González-Lozano, J., Muñiz, J., Cruz Galbán, A., Ruiz, A., Burgos-Martín, A., & Segura, J. M. (2026). From trial to practice: early multicenter real-world experience with the circular pulsed field ablation catheter. Journal of Interventional Cardiac Electrophysiology, 69(9), 2939-2951. https://doi.org/10.1007/s10840-026-02410-x

Vancouver

Ballesteros G, Barrera A, Pérez Castellano N, Mazuelos Bellido F, Fernández-Ruz L, Bertelli G, et al. From trial to practice: early multicenter real-world experience with the circular pulsed field ablation catheter. Journal of Interventional Cardiac Electrophysiology. 2026;69(9):2939-2951. doi:10.1007/s10840-026-02410-x

BibTeX
@article{Ballesteros2026,
  author = {Ballesteros, Gabriel and Barrera, Alberto and Pérez Castellano, Nicasio and Mazuelos Bellido, Francisco and Fernández-Ruz, Leopoldo and Bertelli, Germán and Calvo Cuervo, David and Gutiérrez Ballesteros, Guillermo and González-Lozano, Jaime and Muñiz, Javier and Cruz Galbán, Alba and Ruiz, Amalio and Burgos-Martín, Antonia and Segura, José María},
  title = {From trial to practice: early multicenter real-world experience with the circular pulsed field ablation catheter},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2026},
  volume = {69},
  number = {9},
  pages = {2939--2951},
  doi = {10.1007/s10840-026-02410-x}
}
Kostenlos starten →