Validation of an automated premature ventricular contraction mapping algorithm
Journal of Interventional Cardiac Electrophysiology · 2025
DOI: 10.1007/s10840-025-02150-4 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2025. Verfasst von Yuji Ishida und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Medical University of South Carolina, 30 Courentay Drive, MSC 592, Charleston, SC, 29425-5920, USA. Hauptthemen laut MEDLINE: Ventricular Premature Complexes, Algorithms, Catheter Ablation, Body Surface Potential Mapping. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical University of South Carolina.
Abstract (Originalsprache)
Background
Catheter mapping and ablation of premature ventricular contractions (PVCs) requires accurate annotation of earliest local activation time (LAT), but displacement in catheter position between sinus rhythm (SR) and the PVC complicates three-dimensional mapping localization. An automated algorithm to annotate LAT sites at the corresponding sinus rhythm sites would provide an alternative to manual annotation and improve procedural efficiency.
Methods
A retrospective single center study assessed 64 patients undergoing catheter ablation of PVCs. We divided the study patients into two groups: the patients underwent RF ablation using the CARTO 3 version 7 with LAT-hybrid™ module (hybrid group) and the other patients using the CARTO 3 version 6 without LAT-hybrid™ module (conventional group).
Results
The primary results of this study demonstrate that the mean hybrid distance is 4.03 ± 2.33 mm, and this automated algorithm can correct for the positional shift with accuracy comparable to manual correction. Moreover, this algorithm showed significantly shorter RF time and the shorter PVC offset compared to the conventional method.
Conclusion
PVC mapping with the LAT-hybrid™ module demonstrated that an automated algorithm can map in more detail with no compromise in accuracy. The LAT-hybrid™ module showed significantly shorter RF time and PVC offset from the earliest LAT in LVOT cases. Graphical Abstract Spatial displacement of earliest site of activation for premature ventricular contractions (PVCs) relative to sinus rhythm beats in high-risk para-His bundle region. Automated spatial correction (LAT-Hybrid) provides a more focal area of interest 1.4mm posterior to the His region adjacent to the tricuspid annulus. The LAT-Hybrid automated algorithm directed ablation to the successful site with single burn elimination.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Cardiology, Medical University of South Carolina, 30 Courentay Drive, MSC 592, Charleston, SC, 29425-5920, USA.
- Department of Cardiology, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori, Japan.
- Division of Cardiology, Medical University of South Carolina, 30 Courentay Drive, MSC 592, Charleston, SC, 29425-5920, USA. winterfj@musc.edu.
Förderung
- Medical University of South Carolina
Zitieren
APA
Ishida, Y., Gold, M. R., Payne, J. E., Bainey, A. R., Field, M. E., Badertscher, P., & Winterfield, J. R. (2025). Validation of an automated premature ventricular contraction mapping algorithm. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-025-02150-4
Vancouver
Ishida Y, Gold MR, Payne JE, Bainey AR, Field ME, Badertscher P, et al. Validation of an automated premature ventricular contraction mapping algorithm. Journal of Interventional Cardiac Electrophysiology. 2025. doi:10.1007/s10840-025-02150-4
BibTeX
@article{Ishida2025,
author = {Ishida, Yuji and Gold, Michael R and Payne, Joshua E and Bainey, Adam R and Field, Michael E and Badertscher, Patrick and Winterfield, Jeffrey R},
title = {Validation of an automated premature ventricular contraction mapping algorithm},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2025},
doi = {10.1007/s10840-025-02150-4}
}
EUVIMED