Investigate the relationship between pulsed field ablation parameters and ablation outcomes
Journal of Interventional Cardiac Electrophysiology · 26.08.2024 · 69 (7) · 1669-1685
DOI: 10.1007/s10840-024-01872-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 26.08.2024. Verfasst von Lianru Zang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China. Hauptthemen laut MEDLINE: Liver. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Science and Technology Commission of Shanghai Municipality.
Abstract (Originalsprache)
BACKGROUND: Pulsed field ablation (PFA) is an emerging non-thermal ablation method. The primary challenge is the control of multiple parameters in PFA, as the interplay of these parameters remains unclear in terms of ensuring effective and safe tissue ablation. PURPOSE: This study employs the response surface method (RSM) to explore the interactions between various PFA parameters and ablation outcomes, and seeks to enhance the efficacy and safety of PFA. METHODS: In vivo experiments were conducted using rabbit liver for varying PFA parameters: pulse amplitude (PA), pulse interval (PI), number of pulse trains (NT), and number of pulses in a pulse train (NP). Ablation outcomes assessed included three ablation sizes, surface temperature, and muscle contraction strength. Additionally, histological analysis was performed on the ablated tissue. We analyzed the relationship between PFA parameters and ablation outcomes, and results were then compared with those from a simulation using an electric-thermal coupling PFA finite element model. RESULTS: A linear relationship between ablation outcomes and PFA parameters was established. PA and NT exhibited extremely significant (P 0.97). CONCLUSIONS: This study clarifies the relationship between various PFA parameters and ablation outcomes, and aims to improve the efficacy and safety of PFA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China.
- Cardiac Electrophysiology R&D Center, APT Medical Inc., Shenzhen, 518057, China.
- Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China. sjyan@fudan.edu.cn.
- Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China. xiaomeiwu@fudan.edu.cn.
Förderung
- National Key Research and Development Program of China
- Science and Technology Commission of Shanghai Municipality
Zitieren
APA
Zang, L., Gu, K., Zhou, T., Si, P., Ji, X., Zhang, H., Yan, S., & Wu, X. (2024). Investigate the relationship between pulsed field ablation parameters and ablation outcomes. Journal of Interventional Cardiac Electrophysiology, 69(7), 1669-1685. https://doi.org/10.1007/s10840-024-01872-1
Vancouver
Zang L, Gu K, Zhou T, Si P, Ji X, Zhang H, et al. Investigate the relationship between pulsed field ablation parameters and ablation outcomes. Journal of Interventional Cardiac Electrophysiology. 2024;69(7):1669-1685. doi:10.1007/s10840-024-01872-1
BibTeX
@article{Zang2024,
author = {Zang, Lianru and Gu, Kaihao and Zhou, Tuo and Si, Peng and Ji, Xingkai and Zhang, Hao and Yan, Shengjie and Wu, Xiaomei},
title = {Investigate the relationship between pulsed field ablation parameters and ablation outcomes},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2024},
volume = {69},
number = {7},
pages = {1669--1685},
doi = {10.1007/s10840-024-01872-1}
}