EUVIMEDEUVIMED entdecken
Vergleichsstudie

Quantitative comparison of the isolation lesions between conventional- and larger-sized visually guided laser balloon ablation

Takashi Yamasaki, Ken Kakita, Misun Pak, Tetsuhisa Hattori

Journal of Interventional Cardiac Electrophysiology · 2024

DOI: 10.1007/s10840-024-01738-6 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Takashi Yamasaki und 3 weiteren Autor:innen. Beteiligte Einrichtung: Arrhythmia Care Center, Koseikai Takeda Hospital, 841-5 Higashi Shiokoji-Cho, Shiokoji-Dori Nishinotoin-Higashiiru, Shimogyo-Ku, Kyoto, 600-8558, Jap…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Laser Therapy, Catheter Ablation. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The importance of a wider circumferential isolation of the pulmonary veins (PV), which includes a large portion of the left atrial posterior wall (LAPW), has been suggested in several studies. However, the extended isolation area using a larger inflated visually guided laser balloon (VGLB) ablation remains to be elucidated. METHODS: Seventy-eight patients with atrial fibrillation (AF) who underwent VGLB ablation were enrolled in this prospective study. An electroanatomic map of the left atrium was obtained before and after PV isolation (PVI) using a conventional-sized VGLB. The isolation areas were extended by the largest-sized VGLB ablation and remapped in the same manner. After the ablation, isolation areas were calculated with CARTO-3 system. The one-year atrial arrhythmia (Ata) recurrence was assessed. RESULTS: The largest-sized VGLB ablation yielded statistically greater areas of isolation in left-sided PV antrum (PVA) (11.5 ± 2.3 cm2 vs. 15.9 ± 3.5 cm2, P < .001) and right-sided PVA (14.2 ± 3.3 cm2 vs. 20.6 ± 4.4 cm2, P < .001) than the conventional-sized VGLB. Further, non-ablated LAPW (12.3 ± 4.4 cm2 vs. 7.8 ± 3.9 cm2, P < .001) was significantly reduced after largest-sized VGLB ablation, compared to the conventional-sized VGLB ablation. The one-year Ata freedom was 83.7% in patients with paroxysmal AF and 96.4% in those with persistent AF. CONCLUSION: The largest-sized VGLB ablation technique can create a significantly wider isolation area of PVA and debulk a large amount of LAPW than the conventional-sized VGLB ablation. The one-year outcome was similarly high in paroxysmal and persistent AF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationPulmonary VeinsLaser TherapyCatheter AblationHumansMaleFemaleTreatment OutcomeMiddle AgedProspective StudiesEquipment DesignHeart Conduction SystemSurgery, Computer-AssistedAgedRecurrenceBody Surface Potential Mapping

Stichwörter der Autor:innen

Atrial fibrillationCatheter ablationLaser balloonWide circumferential isolation

Autor:innen und Institutionen

  • Arrhythmia Care Center, Koseikai Takeda Hospital, 841-5 Higashi Shiokoji-Cho, Shiokoji-Dori Nishinotoin-Higashiiru, Shimogyo-Ku, Kyoto, 600-8558, Japan. chanyama0816@hotmail.com.
  • Arrhythmia Care Center, Koseikai Takeda Hospital, 841-5 Higashi Shiokoji-Cho, Shiokoji-Dori Nishinotoin-Higashiiru, Shimogyo-Ku, Kyoto, 600-8558, Japan.

Zitieren

APA

Yamasaki, T., Kakita, K., Pak, M., & Hattori, T. (2024). Quantitative comparison of the isolation lesions between conventional- and larger-sized visually guided laser balloon ablation. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01738-6

Vancouver

Yamasaki T, Kakita K, Pak M, Hattori T. Quantitative comparison of the isolation lesions between conventional- and larger-sized visually guided laser balloon ablation. Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01738-6

BibTeX
@article{Yamasaki2024,
  author = {Yamasaki, Takashi and Kakita, Ken and Pak, Misun and Hattori, Tetsuhisa},
  title = {Quantitative comparison of the isolation lesions between conventional- and larger-sized visually guided laser balloon ablation},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2024},
  doi = {10.1007/s10840-024-01738-6}
}
Kostenlos starten →