The omnipolar mapping technology—a new mapping tool to overcome “bipolar blindness” resulting in true high-density maps
Journal of Interventional Cardiac Electrophysiology · 2023
DOI: 10.1007/s10840-023-01562-4 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2023. Verfasst von Sebastian Dittrich und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrophysiology, Heart Center, University of Cologne, Cologne, Germany. sebastian.dittrich1@uk-koeln.de. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Köln.
Abstract (Originalsprache)
Background
Omnipolar mapping (OT) is a novel tool to acquire omnipolar signals for electro-anatomical mapping, displaying true voltage and real-time wavefront direction and speed independent of catheter orientation. The aim was to analyze previously performed left atrial (LA) and left ventricular (LV) maps for differences using automated OT vs. standard bipolar settings (SD) and HD wave (HDW) algorithm.
Methods
Previously obtained SD and HDW maps of the LA and LV using a 16-electrode, grid-shaped catheter were retrospectively analyzed by applying automated OT, comparing voltage, point density, pulmonary vein (PV) gaps, and LV scar area.
Results
In this analysis, 135 maps of 45 consecutive patients (30 treated for LA, 15 for LV arrhythmia) were included. Atrial maps revealed significantly higher point densities using OT (21471) vs. SD (6682) or HDW (12189, p < 0.001). Mean voltage was significantly higher using OT (0.75 mV) vs. SD (0.61 mV) or HDW (0.64 mV, p < 0.001). OT maps detected significantly more PV gaps per patient vs. SD (4 vs. 2), p = 0.001. In LV maps, OT revealed significantly higher point densities (25951) vs. SD (8582) and HDW (17071), p < 0.001. Mean voltage was significantly higher for OT (1.49 mV) vs. SD (1.19 mV) and HDW (1.2 mV), p < 0.001. Detected scar area was significantly smaller using OT (25.3%) vs. SD (33.9%, p < 0.001).
Conclusion
OT mapping leads to significantly different substrate display, map density, voltage, detection of PV gaps, and scar size, compared to SD and HDW in LA and LV procedures. Successful CA might be facilitated due to true HD maps.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrophysiology, Heart Center, University of Cologne, Cologne, Germany. sebastian.dittrich1@uk-koeln.de.
- Department of Electrophysiology, Heart Center, University of Cologne, Cologne, Germany.
Förderung
- Universitätsklinikum Köln
Zitieren
APA
Dittrich, S., Scheurlen, C., van den Bruck, J. H., Filipovic, K., Wörmann, J., Erlhöfer, S., Schipper, J. H., Lüker, J., Steven, D., & Sultan, A. (2023). The omnipolar mapping technology—a new mapping tool to overcome “bipolar blindness” resulting in true high-density maps. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-023-01562-4
Vancouver
Dittrich S, Scheurlen C, van den Bruck JH, Filipovic K, Wörmann J, Erlhöfer S, et al. The omnipolar mapping technology—a new mapping tool to overcome “bipolar blindness” resulting in true high-density maps. Journal of Interventional Cardiac Electrophysiology. 2023. doi:10.1007/s10840-023-01562-4
BibTeX
@article{Dittrich2023,
author = {Dittrich, Sebastian and Scheurlen, Cornelia and van den Bruck, Jan-Hendrik and Filipovic, Karlo and Wörmann, Jonas and Erlhöfer, Susanne and Schipper, Jan-Hendrik and Lüker, Jakob and Steven, Daniel and Sultan, Arian},
title = {The omnipolar mapping technology—a new mapping tool to overcome “bipolar blindness” resulting in true high-density maps},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2023},
doi = {10.1007/s10840-023-01562-4}
}
EUVIMED