EUVIMEDEUVIMED entdecken
Crossref

Atypical atrial flutter catheter ablation in the era of high-density mapping

Alexandre Raymond-Paquin, Ajay Pillai, Rahul Myadam, Pranav Mankad, Scott Lovejoy, Jayanthi N Koneru, Kenneth A Ellenbogen

Journal of Interventional Cardiac Electrophysiology · 2023

DOI: 10.1007/s10840-023-01475-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2023. Verfasst von Alexandre Raymond-Paquin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Pauley Heart Center, Virginia Commonwealth University, Richmond, VA, USA. alexandre.raymond-paquin@umontreal.ca. Hauptthemen laut MEDLINE: Catheter Ablation, Atrial Flutter, Body Surface Potential Mapping. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Mapping and ablating atypical atrial flutters (AAFLs) have evolved greatly with advances in high-density 3D mapping systems over the last years. METHODS: The objectives are to evaluate the feasibility of AAFL catheter ablation based on high-density mapping and minimizing entrainment and to better characterize AAFL circuits. Consecutive patients who underwent AAFL ablation using the EnSite Precision™ system and HD Grid™ mapping catheter (Abbott, Chicago, IL) between 06/2018 and 1/2022 were included. Mitral isthmus-dependent and roof-dependent AAFLs were classified as conventional circuits. All other AAFL circuits were classified as non-conventional circuits and were defined based on the location of the critical isthmus. RESULTS: Sixty-two patients underwent AAFL ablation (mean age 68±11 years). A total of 95 AAFLs were mapped and 92 (97%) were successfully ablated. Fifty-three (85%) patients had a previous AF/AFL ablation. Forty-four (46%) AAFL circuits were classified as conventional and 51 (54%) as non-conventional. Conventional AAFL circuits had longer critical isthmuses (19.0±9.0 vs 10.8±6.3mm, p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationAtrial FlutterBody Surface Potential MappingHumansFemaleMaleAgedFeasibility StudiesTreatment OutcomeRetrospective StudiesMiddle AgedImaging, Three-Dimensional

Stichwörter der Autor:innen

Activation mappingAtrial flutterAtypical atrial flutterCatheter ablationEntrainment mappingHigh-density mapping

Autor:innen und Institutionen

  • Division of Cardiology, Pauley Heart Center, Virginia Commonwealth University, Richmond, VA, USA. alexandre.raymond-paquin@umontreal.ca.
  • Department of Medicine, Montreal Heart Institute, Université de Montréal, 5000, Bélanger Street, Montreal, Quebec, H1T 1C8, Canada. alexandre.raymond-paquin@umontreal.ca.
  • Division of Cardiology, Pauley Heart Center, Virginia Commonwealth University, Richmond, VA, USA.
  • Abbott Laboratories, Abbott Park, Chicago, IL, USA.

Zitieren

APA

Raymond-Paquin, A., Pillai, A., Myadam, R., Mankad, P., Lovejoy, S., Koneru, J. N., & Ellenbogen, K. A. (2023). Atypical atrial flutter catheter ablation in the era of high-density mapping. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-023-01475-2

Vancouver

Raymond-Paquin A, Pillai A, Myadam R, Mankad P, Lovejoy S, Koneru JN, et al. Atypical atrial flutter catheter ablation in the era of high-density mapping. Journal of Interventional Cardiac Electrophysiology. 2023. doi:10.1007/s10840-023-01475-2

BibTeX
@article{RaymondPaquin2023,
  author = {Raymond-Paquin, Alexandre and Pillai, Ajay and Myadam, Rahul and Mankad, Pranav and Lovejoy, Scott and Koneru, Jayanthi N and Ellenbogen, Kenneth A},
  title = {Atypical atrial flutter catheter ablation in the era of high-density mapping},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2023},
  doi = {10.1007/s10840-023-01475-2}
}
Kostenlos starten →