EUVIMEDEUVIMED entdecken
Crossref

Success rate in micropulse diode laser treatment with regard to lens status, refractive errors, and glaucoma subtypes

Virginia Zanutigh, Luciano Daniel Perrone, Gastón Gómez-Caride, Franco Perrone, Gerardo Valvecchia, Celina Logioco

International Ophthalmology · 2023

DOI: 10.1007/s10792-023-02640-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, 2023. Verfasst von Virginia Zanutigh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centro de Ojos Quilmes, Humberto Primo, 298, Quilmes, Buenos Aires, Argentina. virginiazanutigh@gmail.com. Hauptthemen laut MEDLINE: Glaucoma, Open-Angle, Glaucoma, Refractive Errors. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the efficacy of micropulse transscleral cyclophotocoagulation (MP-TSCPC) considering different characteristics: glaucoma subtypes and lens status. METHODS: A retrospective case-series study was designed to evaluate intraocular pressure (IOP), and the number of IOP-lowering medications, used by glaucoma patients treated with MP-TSCPC between 2016 and 2019. Cases had a follow-up period of 12 months. Achieving an IOP reduction higher than 20%, or the decrease of at least one IOP-lowering medication, was considered a successful outcome. The same population was analyzed by classifying them in two groups as: glaucoma subtypes and lens status. The baseline spherical equivalent (SE) was also calculated for considering association with the achieved IOP. RESULTS: A total of 86 eyes were included. In most cases, IOP and IOP-lowering medications were decreased with a statistically significant difference (p < 0.0001), and all of them had a successful outcome. The percentage of IOP drop oscillated between 25.9% (open-angle glaucoma sub-group) and 37.5% (pseudoexfoliative glaucoma sub-group), 12 months after surgery. The difference between the groups was not statistically significant (p 0.20 and 0.32 for glaucoma subtypes and lens status, respectively). The Pearson's coefficient obtained was low for the SE and IOP association, at the 12 -month postoperative mark (- 0.009; p < 0.001). CONCLUSIONS: The MP-TSCPC treatment was successful in decreasing IOP and IOP-lowering medications, in different glaucoma subtypes. Differences between groups (glaucoma subtypes, phakic and pseudophakic eyes) were not statistically significant. No association was found between the SE and the IOP achieved value after MS-TSCPC treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glaucoma, Open-AngleGlaucomaRefractive ErrorsHumansRetrospective StudiesLasers, SemiconductorTreatment OutcomeLaser CoagulationVisual AcuityIntraocular PressureCiliary Body

Stichwörter der Autor:innen

GlaucomaLaser treatmentMicropulse transscleral cyclophotocoagulationRefractive errorSpherical equivalent

Autor:innen und Institutionen

  • Centro de Ojos Quilmes, Humberto Primo, 298, Quilmes, Buenos Aires, Argentina. virginiazanutigh@gmail.com.
  • Centro de Ojos Quilmes, Humberto Primo, 298, Quilmes, Buenos Aires, Argentina.

Zitieren

APA

Zanutigh, V., Perrone, L. D., Gómez-Caride, G., Perrone, F., Valvecchia, G., & Logioco, C. (2023). Success rate in micropulse diode laser treatment with regard to lens status, refractive errors, and glaucoma subtypes. International Ophthalmology. https://doi.org/10.1007/s10792-023-02640-2

Vancouver

Zanutigh V, Perrone LD, Gómez-Caride G, Perrone F, Valvecchia G, Logioco C. Success rate in micropulse diode laser treatment with regard to lens status, refractive errors, and glaucoma subtypes. International Ophthalmology. 2023. doi:10.1007/s10792-023-02640-2

BibTeX
@article{Zanutigh2023,
  author = {Zanutigh, Virginia and Perrone, Luciano Daniel and Gómez-Caride, Gastón and Perrone, Franco and Valvecchia, Gerardo and Logioco, Celina},
  title = {Success rate in micropulse diode laser treatment with regard to lens status, refractive errors, and glaucoma subtypes},
  journal = {International Ophthalmology},
  year = {2023},
  doi = {10.1007/s10792-023-02640-2}
}
Kostenlos starten →