Relationship between the partial blink rate and ocular surface parameters
International Ophthalmology · 2021-07 · 41 (7) · 2601-2608
DOI: 10.1007/s10792-021-01819-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 25.03.2021. Verfasst von Young Joon Jeon und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, 136 Youngshinro, Youngdeungpo-gu, Seoul, 07301, Republic of …. Hauptthemen laut MEDLINE: Blinking, Dry Eye Syndromes. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
PURPOSE: To elucidate the relationship between partial blink rate (PBR) and ocular surface parameters. METHODS: We conducted a retrospective cross-sectional study of the patients who visited the Kim's Eye Hospital between March 2020 and July 2020. Blinking dynamics, tear film lipid layer thickness (LLT), non-invasive tear film break- up time (NITBUT), tear meniscus height (TMH), and meibomian gland (MG) dropout rate were assessed using the IDRA® Ocular surface analyzer (SBM SISTEMI, Inc., Torino, Italy) (IDRA). Dry eye symptoms were quantified by the Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire scores. RESULTS: A total of 47 non-Sjögren dry eye patients (47 right eyes, mean age = 56.8 ± 14.5 [20-75] years, 66% female) were enrolled. Among the ocular surface parameters, PBR had strong correlations with MG dropout rate (r = 0.811; p < 0.01) and moderate correlations with SPEED scores (r = 0.596; p < 0.01). MG dropout rate and age had moderate correlations with SPEED scores (r = 0.416; p = 0.04 and r = 0.322; p = 0.03, respectively). Comparisons by sex revealed no significant difference in characteristics, except for the TMH value. The TMH of female patients (0.17 ± 0.07) was significantly higher than that of males (0.14 ± 0.04; p = 0.04). LLT showed no significant correlation with the other variables. CONCLUSION: PBR and MG dropout rates measured with IDRA were significantly correlated to dry eye symptoms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, 136 Youngshinro, Youngdeungpo-gu, Seoul, 07301, Republic of Korea.
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, 136 Youngshinro, Youngdeungpo-gu, Seoul, 07301, Republic of Korea. kmkoh@kimeye.com.
Zitieren
APA
Jeon, Y. J., Song, M. Y., Kim, K. Y., Hwang, K. Y., Kwon, Y. A., & Koh, K. (2021). Relationship between the partial blink rate and ocular surface parameters. International Ophthalmology, 41(7), 2601-2608. https://doi.org/10.1007/s10792-021-01819-9
Vancouver
Jeon YJ, Song MY, Kim KY, Hwang KY, Kwon YA, Koh K. Relationship between the partial blink rate and ocular surface parameters. International Ophthalmology. 2021;41(7):2601-2608. doi:10.1007/s10792-021-01819-9
BibTeX
@article{Jeon2021,
author = {Jeon, Young Joon and Song, Mi Yeon and Kim, Kook Young and Hwang, Kyu-Yeon and Kwon, Young-A and Koh, Kyungmin},
title = {Relationship between the partial blink rate and ocular surface parameters},
journal = {International Ophthalmology},
year = {2021},
volume = {41},
number = {7},
pages = {2601--2608},
doi = {10.1007/s10792-021-01819-9}
}
EUVIMED