Comparison of upper eyelid pressure and ocular surface parameters in dry eye disease and benign essential Blepharospasm: A cross-sectional study
Contact Lens and Anterior Eye · 2024
DOI: 10.1016/j.clae.2024.102298 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Contact Lens and Anterior Eye, 2024. Verfasst von Guohong Zhao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual …. Hauptthemen laut MEDLINE: Dry Eye Syndromes, Blepharospasm, Eyelids, Pressure. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China, Beijing Natural Science Foundation, Beijing Nova Program.
Abstract (Originalsprache)
PURPOSE: To compare the upper eyelid pressure (UEP) and ocular surface parameters between dry eye disease (DED) and DED coexisting with benign essential blepharospasm (BEB), exploring which parameters could assist in distinguishing between DED and BEB, as potential risk factors for DED with BEB. METHODS: All enrolled participants diagnosed with DED or DED coexisting with BEB were initially subjected to ocular surface disease index (OSDI) determination. Subsequently, the upper eyelid pressure was recorded using an innovative eyelid pressure measurement device, followed by a series of ocular surface examinations. The two groups were compared using the independent t-test and Mann-Whitney U test. A logistic regression analysis was performed to identify which parameters can predict the onset of blepharospasm. RESULTS: The BEB group achieved a higher upper eyelid pressure (101.9 ± 23.5mN vs 88.4 ± 18.1mN, P = 0.009), lower number of total blink (6.2 ± 4.2 vs 7.1 ± 4.1, P = 0.016), higher corneal fluorescein staining score (4.0 ± 1.9 vs 3.0 ± 1.7, P = 0.046), higher partial blink rate (0.9 ± 0.2 vs 0.5 ± 0.4, P = 0.000) and the lower grade of meibum expressibility (1 (1, 2) vs 2 (1, 3), P = 0.000) and meibum quality (1 (1, 1) vs 1 (1, 1), P = 0.033) compared with the DED group. The upper eyelid pressure (OR = 1.123), partial blink rate (OR = 0.014) and the grade of meibum expressibility (OR = 10.804) showed significant associations with BEB (P < 0.05). CONCLUSION: Despite similar OSDI scores, DED coexisting with BEB exhibited higher upper eyelid pressure, lower corneal fluorescein staining score, lower partial blink rate, more total blinks, lower grades of meibum expressibility, and lower meibum quality compared to DED alone. Among these, higher upper eyelid pressure, lower partial blink rate, and worse grade of meibum expressibility were identified as risk factors for BEB in DED.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China.
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China; Beijing Advanced Innovation C…
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China. Electronic address: jie_yingc…
Förderung
- National Natural Science Foundation of China
- Beijing Natural Science Foundation
- Beijing Nova Program
Zitieren
APA
Zhao, G., Wang, J., Ma, Q., Hao, Y., Tian, L., & Jie, Y. (2024). Comparison of upper eyelid pressure and ocular surface parameters in dry eye disease and benign essential Blepharospasm: A cross-sectional study. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2024.102298
Vancouver
Zhao G, Wang J, Ma Q, Hao Y, Tian L, Jie Y. Comparison of upper eyelid pressure and ocular surface parameters in dry eye disease and benign essential Blepharospasm: A cross-sectional study. Contact Lens and Anterior Eye. 2024. doi:10.1016/j.clae.2024.102298
BibTeX
@article{Zhao2024,
author = {Zhao, Guohong and Wang, Jingyi and Ma, Qian and Hao, Yiran and Tian, Lei and Jie, Ying},
title = {Comparison of upper eyelid pressure and ocular surface parameters in dry eye disease and benign essential Blepharospasm: A cross-sectional study},
journal = {Contact Lens and Anterior Eye},
year = {2024},
doi = {10.1016/j.clae.2024.102298}
}
EUVIMED