Diagnostic performance of Shear Wave Elastography and high-resolution ultrasound in non-melanoma skin cancer: a study of basal and squamous cell carcinomas
Medical Ultrasonography · 2025
DOI: 10.11152/mu-4540 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Ultrasonography, 2025. Verfasst von Amalia Moisoiu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, County Emergency Clinical Hospital, "Iuliu Hațieganu" University of Medicine and Pharmacy, Cluj-Napoca. Hauptthemen laut MEDLINE: Skin Neoplasms, Elasticity Imaging Techniques, Carcinoma, Squamous Cell, Basal Cell Carcinoma.
Abstract (Originalsprache)
Aims
This study aimed to evaluate the diagnostic performance of shear wave elastography (SWE) in differentiating non-melanoma skin cancer (NMSC), including basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), from benign skin lesions. A secondary objective was to assess the accuracy of high-resolution ultrasonography (HRUS) for preoperative tumormeasurement.Material and methods: A prospective study was conducted on 106 patients with clinically suspected NMSC or benign lesions (nevi). Each lesion was evaluated with SWE and HRUS using an 18 MHz probe, followed by surgical excision and histopathological confirmation. Among the confirmed malignancies, 46 were BCC and 15 SCC. The control group included 35 nevi diagnosed clinically and dermatoscopically. SWE stiffness values were compared across lesion types. Tumor length and depth measured by HRUS were validated against pathology using The Student’s t-test or Mann–Whitney U test, Bland–Altman analysis and the Intraclass Correlation Coefficient (ICC).
Results
SWE showed significantly higher stiffness in malignant versus benign lesions, with optimal thresholds of >13 kPa for BCC and >15 kPa for SCC. The area under the receiver operating characteristic curve (AUROC), was 0.95 for BCC and 0.99 for SCC. Differentiation between SCC and BCC was moderate (AUROC=0.70). HRUS accurately estimated tumor length (bias=1.31 mm, p>0.05; ICC=0.90), while depth was slightly overestimated (bias=0.87 mm, p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Dermatology, County Emergency Clinical Hospital, "Iuliu Hațieganu" University of Medicine and Pharmacy, Cluj-Napoca.
- Radiology Department, "Iuliu Hațieganu" University of Medicine and Pharmacy, Cluj-Napoca.
- Clinical Institute of Urology and Renal Transplantation, Cluj-Napoca.
- Interservisan Medical-Surgical Center, Cluj-Napoca.
- Interservisan Medical-Surgical Center, "Iuliu Hațieganu" University of Medicine and Pharmacy, Cluj-Napoca.
- Department of Dermatology, County Emergency Clinical Hospital, Cluj-Napoca.
Zitieren
APA
Moisoiu, A., Solomon, C. M., Moisoiu, T., Bocsa, C., Filip, A., Baican, C., Ungureanu, L., Dănescu, S., Șenilă, S., Baican, A., & Fodor, D. (2025). Diagnostic performance of Shear Wave Elastography and high-resolution ultrasound in non-melanoma skin cancer: a study of basal and squamous cell carcinomas. Medical Ultrasonography. https://doi.org/10.11152/mu-4540
Vancouver
Moisoiu A, Solomon CM, Moisoiu T, Bocsa C, Filip A, Baican C, et al. Diagnostic performance of Shear Wave Elastography and high-resolution ultrasound in non-melanoma skin cancer: a study of basal and squamous cell carcinomas. Medical Ultrasonography. 2025. doi:10.11152/mu-4540
BibTeX
@article{Moisoiu2025,
author = {Moisoiu, Amalia and Solomon, Carolina Maria and Moisoiu, Tudor and Bocsa, Corina and Filip, Adriana and Baican, Corina and Ungureanu, Loredana and Dănescu, Sorina and Șenilă, Simona and Baican, Adrian and Fodor, Daniela},
title = {Diagnostic performance of Shear Wave Elastography and high-resolution ultrasound in non-melanoma skin cancer: a study of basal and squamous cell carcinomas},
journal = {Medical Ultrasonography},
year = {2025},
doi = {10.11152/mu-4540}
}
EUVIMED