EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Reproducibility and reliability of flow quantification using CMR 2D-phase contrast and 4D-Flow in secondary mitral valve regurgitation

Yasaman Safarkhanlo, Martina Boscolo Berto, Giancarlo Spano, Benedikt Bernhard, Jonathan Schütze, Anselm W Stark, Fabien Praz, Isaac Shiri, Alan A Peters, Christof Schaub, Eva S Peper, Chrysoula Garefa und 3 weitere

The International Journal of Cardiovascular Imaging · 16.05.2025 · 41 (7) · 1341-1350

DOI: 10.1007/s10554-025-03421-x ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, online erschienen am 16.05.2025. Verfasst von Yasaman Safarkhanlo und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Inselspital, University Hospital Bern, Bern, CH-3010, Switzerland. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Mitral Valve, Hemodynamics, Magnetic Resonance Imaging, Cine. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Bern.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate quantification of mitral valve regurgitation (MVR) is crucial for patient management. While different MVR quantification methods based on cardiac magnetic resonance imaging (CMR) exist, their reproducibility and reliability remain uncertain. This study aims to evaluate the reproducibility of different CMR 2D-phase contrast (PC) and 4D-flow MVR quantification methods. The inter-reader and intra-reader reproducibility were assessed using intraclass correlation coefficients (ICC). Seven methods were evaluated: 2D-PC standard (LVSV minus aortic flow), 2D-PC mitral-aortic (mitral inflow minus aortic flow), 2D-PC direct (quantifying mitral backflow), 4D-flow standard, 4D-flow mitral-aortic, 4D-flow direct, and volumetric method (LVSV minus RVSV) in 32 patients (74.8 ± 9.8 years, 28% females) with secondary MVR, analyzed independently by two experienced readers. A total of 26 patients were included in the analysis for 2D-PC and 15 for 4D-flow methods. Among all techniques, 2D-PC standard was the most reliable method with both good inter-reader (ICC = 0.85, p < 0.001) and intra-reader agreement (ICC = 0.87, p < 0.001). The 4D-flow standard (ICC = 0.97, p < 0.001) and the volumetric method (ICC = 0.81, p < 0.001) showed excellent and good intra-reader agreements, respectively, but only moderate inter-reader reproducibility (ICC = 0.52, p = 0.027 and ICC = 0.71, p < 0.001). In patients with secondary MVR, 2D-PC standard method demonstrated the highest reproducibility, while 4D-flow methods showed excellent intra-reader reliability but more variable inter-reader agreement. Standardized post-processing protocols and training would likely enhance the clinical application of these techniques. Future studies should investigate these methods in larger, diverse cohorts and correlate findings with clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral Valve InsufficiencyMitral ValveHemodynamicsMagnetic Resonance Imaging, CineImage Interpretation, Computer-AssistedMyocardial Perfusion ImagingHumansReproducibility of ResultsFemaleMalePredictive Value of TestsAgedObserver VariationAged, 80 and overBlood Flow VelocityMiddle AgedRetrospective Studies

Stichwörter der Autor:innen

2D-PC4D-flowCardiovascularChallengesData analysisFlowHeartValidationValvesVelocity & flow

Autor:innen und Institutionen

  • Department of Cardiology, Inselspital, University Hospital Bern, Bern, CH-3010, Switzerland.
  • Graduate School for Cellular and Biomedical Sciences (GCB), University of Bern, Bern, Switzerland.
  • Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland.
  • Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, University Hospital Bern, Bern, Switzerland.
  • Department of Cardiology, Inselspital, University Hospital Bern, Bern, CH-3010, Switzerland. christoph.graeni@insel.ch.
  • Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland. christoph.graeni@insel.ch.

Förderung

  • University of Bern

Zitieren

APA

Safarkhanlo, Y., Berto, M. B., Spano, G., Bernhard, B., Schütze, J., Stark, A. W., Praz, F., Shiri, I., Peters, A. A., Schaub, C., Peper, E. S., Garefa, C., Wahl, A., Bastiaansen, J. A. M., & Gräni, C. (2025). Reproducibility and reliability of flow quantification using CMR 2D-phase contrast and 4D-Flow in secondary mitral valve regurgitation. The International Journal of Cardiovascular Imaging, 41(7), 1341-1350. https://doi.org/10.1007/s10554-025-03421-x

Vancouver

Safarkhanlo Y, Berto MB, Spano G, Bernhard B, Schütze J, Stark AW, et al. Reproducibility and reliability of flow quantification using CMR 2D-phase contrast and 4D-Flow in secondary mitral valve regurgitation. The International Journal of Cardiovascular Imaging. 2025;41(7):1341-1350. doi:10.1007/s10554-025-03421-x

BibTeX
@article{Safarkhanlo2025,
  author = {Safarkhanlo, Yasaman and Berto, Martina Boscolo and Spano, Giancarlo and Bernhard, Benedikt and Schütze, Jonathan and Stark, Anselm W and Praz, Fabien and Shiri, Isaac and Peters, Alan A and Schaub, Christof and Peper, Eva S and Garefa, Chrysoula and Wahl, Andreas and Bastiaansen, Jessica A M and Gräni, Christoph},
  title = {Reproducibility and reliability of flow quantification using CMR 2D-phase contrast and 4D-Flow in secondary mitral valve regurgitation},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2025},
  volume = {41},
  number = {7},
  pages = {1341--1350},
  doi = {10.1007/s10554-025-03421-x}
}
Kostenlos starten →