Assessment of the correlation between Doppler derived dP/dt and aortic velocity-time integral during cardiac resynchronization therapy optimization
The International Journal of Cardiovascular Imaging · 2024
DOI: 10.1007/s10554-024-03204-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2024. Verfasst von Selim Ekinci und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Tepecik Training and Research Hospital, University of Health Sciences, Izmir, Turkey. mdsekinci@gmail.com. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Predictive Value of Tests, Ventricular Function, Left, Myocardial Contraction. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Suboptimal response to cardiac resynchronization therapy (CRT) may be improved by optimization of device parameters using echocardiography. For this purpose, the aortic velocity-time integral (aVTI) has been used as a target metric to define optimal velocity timings for each ventricle. dP/dt is a parameter used for the assessment of myocardial contractility. In this study, we aimed to evaluate the effectiveness of Doppler-derived dP/dt in optimization by assessing the possible correlation between aVTI and dP/dt. METHODS: Patients with CRT admitted for routine follow-up were included in the study. Aortic VTI and dP/dt measurements were recorded in four different standard pacing configurations during reprogramming. RESULTS: A total of 45 patients were included in the final analysis. No correlation was found between the aVTI and the delta dP/dt value in the two configurations where the change in dP/dt was maximum (p = 0.894). In the two configurations where the change in aVTI was maximum, there was also no correlation between the delta dP/dt and the delta aVTI (p = 0.715). When patients were dichotomized according to the median value of dP/dt, there were no differences in aVTI, NYHA classes, LVEF, and mitral regurgitation (MR) severity (p = 0.4; p = 0.5; p = 0.7; p = 0.3; respectively). The change in both dP/dt and aVTI was statistically significant when switching from RV-only to QRS width-targeted configuration (p = 0.001; p = 0.041; respectively). CONCLUSION: In conclusion, aVTI recorded at different pacing configurations did not correlate with dP/dt during interventricular optimization. However, both parameters consistently showed a positive effect of biventricular pacing on contractile synchronization and stroke volume.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Tepecik Training and Research Hospital, University of Health Sciences, Izmir, Turkey. mdsekinci@gmail.com.
- Department of Cardiology, Tepecik Training and Research Hospital, University of Health Sciences, Izmir, Turkey.
Zitieren
APA
Ekinci, S., & Uzun, H. G. (2024). Assessment of the correlation between Doppler derived dP/dt and aortic velocity-time integral during cardiac resynchronization therapy optimization. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-024-03204-w
Vancouver
Ekinci S, Uzun HG. Assessment of the correlation between Doppler derived dP/dt and aortic velocity-time integral during cardiac resynchronization therapy optimization. The International Journal of Cardiovascular Imaging. 2024. doi:10.1007/s10554-024-03204-w
BibTeX
@article{Ekinci2024,
author = {Ekinci, Selim and Uzun, Hakan Gökalp},
title = {Assessment of the correlation between Doppler derived dP/dt and aortic velocity-time integral during cardiac resynchronization therapy optimization},
journal = {The International Journal of Cardiovascular Imaging},
year = {2024},
doi = {10.1007/s10554-024-03204-w}
}
EUVIMED