EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A perfusable device for hypoxia studies under continuous flow

Karim Ameziane, Niyati Kandikanti, Joose Kreutzer, Hannu Välimäki, Meenakshisundaram Kandhavelu, Veikko Sariola, Pasi Kallio

Biomedical Microdevices · 2026-12 · 28 (4)

DOI: 10.1007/s10544-026-00857-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Microdevices, online erschienen am 23.11.2026. Verfasst von Karim Ameziane und 6 weiteren Autor:innen. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tampere University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to the central role of oxygen, Organ-on-Chip (OoC) platforms that control oxygen conditions are key to modelling and understanding tissue behaviour, including the development of diseases and their treatment. For example, glioblastoma (GBM) is characterized by extreme intratumoural heterogeneity, including steep oxygen gradients from perivascular regions to necrotic cores. In this study, we introduce a PDMS-based OoC device designed to set and maintain desired oxygen levels within its cell culture region under continuous perfusion. The device can be prepared on a standard microscopy slide and consists of a medium channel surrounded by a gas channel, separated by a PDMS wall enabling gas exchange of the perfused medium. With real-time oxygen imaging, it was determined that hypoxic conditions can be set within the device in 54 min when a flow rate of 4 µL/min is used. The maximum operating flow rate, at which it can maintain the set hypoxia, was determined to be 10 µL/min, providing hypoxic conditions in approximately 34 min. A finite element method (FEM) replica of the device was also developed in silico to predict the behaviour under a large range of conditions. This model estimates that the shear stress in the cell culture region remains under 0.6 mPa at the maximum operating flow rate. Finally, we demonstrate the use of the device by cultivating GBM cells in the device under normoxic and hypoxic conditions. Their hypoxic response in the device was confirmed with an intracellular fluorescent hypoxia probe.

Förderung

  • Tampere University

Zitieren

APA

Ameziane, K., Kandikanti, N., Kreutzer, J., Välimäki, H., Kandhavelu, M., Sariola, V., & Kallio, P. (2026). A perfusable device for hypoxia studies under continuous flow. Biomedical Microdevices, 28(4). https://doi.org/10.1007/s10544-026-00857-3

Vancouver

Ameziane K, Kandikanti N, Kreutzer J, Välimäki H, Kandhavelu M, Sariola V, et al. A perfusable device for hypoxia studies under continuous flow. Biomedical Microdevices. 2026;28(4). doi:10.1007/s10544-026-00857-3

BibTeX
@article{Ameziane2026,
  author = {Ameziane, Karim and Kandikanti, Niyati and Kreutzer, Joose and Välimäki, Hannu and Kandhavelu, Meenakshisundaram and Sariola, Veikko and Kallio, Pasi},
  title = {A perfusable device for hypoxia studies under continuous flow},
  journal = {Biomedical Microdevices},
  year = {2026},
  volume = {28},
  number = {4},
  doi = {10.1007/s10544-026-00857-3}
}
Kostenlos starten →