A Non-Invasive Continuous Respiration Rate Monitoring Device for Dairy Cattle Under Commercial Farm Conditions
Animals · 21.03.2026 · 16 (6) · 984
DOI: 10.3390/ani16060984 ↗Kurz gefasst
Fachartikel in der Zeitschrift Animals, online erschienen am 21.03.2026. Verfasst von Mathias Eisner und 8 weiteren Autor:innen. Beteiligte Einrichtung: smaXtec Animal Care GmbH, Sandgasse 36/2, A-8010 Graz, Austria. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: smaXtec Animal Care GmbH.
Abstract (Originalsprache)
Respiration rate (RR) is a key physiological indicator of health, stress, and thermoregulatory load in dairy cattle, yet continuous RR monitoring under commercial farm conditions remains challenging. In this Technical Note, we present a non-invasive clip-on nose ring device for continuous respiration monitoring based on acoustic recording directly at the nostril. The device integrates a MEMS microphone, embedded electronics, battery, and removable storage in a sealed, mechanically robust housing suitable for real-world barn environments. The system was deployed on five dairy cows under commercial farm conditions, enabling repeated multi-day recordings over several weeks. The respiration rate was extracted offline from raw audio using a deterministic signal-processing pipeline based on multiscale periodicity detection. Algorithm-derived RR estimates were evaluated against manually annotated breath events. Using 10-min rolling median values, the algorithm achieved a mean absolute error (MAE) of 1.47 breaths per minute (bpm), a root mean square error (RMSE) of 1.92 bpm, and a high correlation with reference values (r = 0.98, R2 = 0.96). In addition to short-term accuracy, the system enabled stable multi-day monitoring. Group-level analysis across all five animals revealed a clear diurnal respiration pattern over multiple consecutive days, with lower RR during nighttime and higher RR during daytime summer conditions, without signs of a baseline drift. These results demonstrate the feasibility of continuous, long-term respiration monitoring in dairy cattle using an audio-based clip-on nose ring device and provide a practical foundation for longitudinal (multi-day, within-animal) RR assessment under commercial farm conditions, with potential for future extensions towards advanced respiratory health monitoring. While the system demonstrated stable performance under summer farm conditions, validation under extreme heat-stress environments and larger animal cohorts is required for comprehensive population-level assessment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- smaXtec Animal Care GmbH, Sandgasse 36/2, A-8010 Graz, Austria.
- Institute of Livestock Research, Agricultural Research and Education Centre Raumberg-Gumpenstein, Alt-Irdning 11, A-8952 Irdning-Donnersbachtal, Austria.
ORCID-Profile: Mathias Eisner, Oliver Orasch, Philipp Breitegger
Förderung
- smaXtec Animal Care GmbH
Zitieren
APA
Eisner, M., Jedinger, M., Eingang, D., Raggl, M., Frech, M., Lenzelbauer, P., Harant, M., Orasch, O., & Breitegger, P. (2026). A Non-Invasive Continuous Respiration Rate Monitoring Device for Dairy Cattle Under Commercial Farm Conditions. Animals, 16(6), 984. https://doi.org/10.3390/ani16060984
Vancouver
Eisner M, Jedinger M, Eingang D, Raggl M, Frech M, Lenzelbauer P, et al. A Non-Invasive Continuous Respiration Rate Monitoring Device for Dairy Cattle Under Commercial Farm Conditions. Animals. 2026;16(6):984. doi:10.3390/ani16060984
BibTeX
@article{Eisner2026,
author = {Eisner, Mathias and Jedinger, Manuel and Eingang, Daniel and Raggl, Manuel and Frech, Manuel and Lenzelbauer, Peter and Harant, Michael and Orasch, Oliver and Breitegger, Philipp},
title = {A Non-Invasive Continuous Respiration Rate Monitoring Device for Dairy Cattle Under Commercial Farm Conditions},
journal = {Animals},
year = {2026},
volume = {16},
number = {6},
pages = {984},
doi = {10.3390/ani16060984}
}
EUVIMED