EUVIMEDEUVIMED entdecken
Crossref

Magnetic moment orientation compensation of a magnetic navigated underactuated spherical capsule robot for all-around observation

Yongshun Zhang, Yunhui Ma, Yanxia Li, Lin Li

Biomedical Microdevices · 2026-06 · 28 (2)

DOI: 10.1007/s10544-026-00811-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Microdevices, online erschienen am 27.04.2026. Verfasst von Yongshun Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Intelligent Manufacture Engineering, Guangdong Baiyun University, Guangzhou, 510450, China. zyshun@dlut.edu.cn. Hauptthemen laut MEDLINE: Robotics, Magnetic Fields, Capsule Endoscopes. Die Arbeit nennt 28 Literaturangaben. Gefördert von: the National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

All-around disease screening in any appointed position in 3D regions of the gastrointestinal (GI) tract such as esophagus, stomach and colon is still a pending issue. Based on the rotating magnetic coaxial effect of a suspended magnet actuated by the spatial universal rotating magnetic field (SURMF), a novel underactuated spherical capsule robot(USCR) with fully suspended magnetic ring in term of the gyroscope dynamic balance, along with its lateral drive method using rotating coaxial magnetic moment, are proposed to address orthogonal decoupling of magnetic moments, flexible and efficient posture control with good stability. The underactuated structure facilitates the all around observation mode at a fixed-point and the rolling locomotion mode by the space universal rotating magnetic field (SURMF) axis manipulation, however, magnetic moment orientation deviation and motion path deviation are caused by the slip angle, thus deviation model of the decoupled rotating coaxial magnetic moment is derived, corrected and verified, which lays a foundation for the precise and stable control of the motion path by the slip angle compensation and the application of the rotating coaxial driving theory of the novel capsule.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RoboticsMagnetic FieldsCapsule EndoscopesEquipment Design

Autor:innen und Institutionen

  • College of Intelligent Manufacture Engineering, Guangdong Baiyun University, Guangzhou, 510450, China. zyshun@dlut.edu.cn.
  • Key Laboratory for Precision and Non-Traditional Machining Technology, Ministry of Education, Dalian University of Technology, Dalian, China. zyshun@dlut.edu.cn.
  • Key Laboratory for Precision and Non-Traditional Machining Technology, Ministry of Education, Dalian University of Technology, Dalian, China.
  • College of Intelligent Manufacture Engineering, Guangdong Baiyun University, Guangzhou, 510450, China.

Förderung

  • the National Natural Science Foundation of China

Zitieren

APA

Zhang, Y., Ma, Y., Li, Y., & Li, L. (2026). Magnetic moment orientation compensation of a magnetic navigated underactuated spherical capsule robot for all-around observation. Biomedical Microdevices, 28(2). https://doi.org/10.1007/s10544-026-00811-3

Vancouver

Zhang Y, Ma Y, Li Y, Li L. Magnetic moment orientation compensation of a magnetic navigated underactuated spherical capsule robot for all-around observation. Biomedical Microdevices. 2026;28(2). doi:10.1007/s10544-026-00811-3

BibTeX
@article{Zhang2026,
  author = {Zhang, Yongshun and Ma, Yunhui and Li, Yanxia and Li, Lin},
  title = {Magnetic moment orientation compensation of a magnetic navigated underactuated spherical capsule robot for all-around observation},
  journal = {Biomedical Microdevices},
  year = {2026},
  volume = {28},
  number = {2},
  doi = {10.1007/s10544-026-00811-3}
}
Kostenlos starten →