EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Video-based beat-by-beat blood pressure monitoring via transfer deep-learning

Osama A. Omer, Mostafa Salah, Loay Hassan, Ahmed Abdelreheem, Ammar M. Hassan

Applied Intelligence · 2024-03 · 54 (6) · 4564-4584

DOI: 10.1007/s10489-024-05354-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Intelligence, online erschienen am 01.04.2024. Verfasst von Osama A. Omer und 4 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 138 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Information Technology Industry Development Agency.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Currently, learning physiological vital signs such as blood pressure (BP), hemoglobin levels, and oxygen saturation, from Photoplethysmography (PPG) signal, is receiving more attention. Despite successive progress that has been made so far, continuously revealing new aspects characterizes that field as a rich research topic. It includes a diverse number of critical points represented in signal denoising, data cleaning, employed features, feature format, feature selection, feature domain, model structure, problem formulation (regression or classification), and model combinations. It is worth noting that extensive research efforts are devoted to utilizing different variants of machine learning and deep learning models while transfer learning is not fully explored yet. So, in this paper, we are introducing a per-beat rPPG-to-BP mapping scheme based on transfer learning. An interesting representation of a 1-D PPG signal as a 2-D image is proposed for enabling powerful off-the-shelf image-based models through transfer learning. It resolves limitations about training data size due to strict data cleaning. Also, it enhances model generalization by exploiting underlying excellent feature extraction. Moreover, non-uniform data distribution (data skewness) is partially resolved by introducing logarithmic transformation. Furthermore, double cleaning is applied for training contact PPG data and testing rPPG beats as well. The quality of the segmented beats is tested by checking some of the related quality metrics. Hence, the prediction reliability is enhanced by excluding deformed beats. Varying rPPG quality is relaxed by selecting beats during intervals of the highest signal strength. Based on the experimental results, the proposed system outperforms the state-of-the-art systems in the sense of mean absolute error (MAE) and standard deviation (STD). STD for the test data is decreased to 5.4782 and 3.8539 for SBP and DBP, respectively. Also, MAE decreased to 2.3453 and 1.6854 for SBP and DBP, respectively. Moreover, the results for BP estimation from real video reveal that the STD reaches 8.027882 and 6.013052 for SBP and DBP, respectively. Also, MAE for the estimated BP from real videos reaches 7.052803 and 5.616028 for SBP and DBP, respectively. Graphical abstract Proposed camera-based blood pressure monitoring system

Förderung

  • Information Technology Industry Development Agency

Zitieren

APA

Omer, O. A., Salah, M., Hassan, L., Abdelreheem, A., & Hassan, A. M. (2024). Video-based beat-by-beat blood pressure monitoring via transfer deep-learning. Applied Intelligence, 54(6), 4564-4584. https://doi.org/10.1007/s10489-024-05354-9

Vancouver

Omer OA, Salah M, Hassan L, Abdelreheem A, Hassan AM. Video-based beat-by-beat blood pressure monitoring via transfer deep-learning. Applied Intelligence. 2024;54(6):4564-4584. doi:10.1007/s10489-024-05354-9

BibTeX
@article{Omer2024,
  author = {Omer, Osama A. and Salah, Mostafa and Hassan, Loay and Abdelreheem, Ahmed and Hassan, Ammar M.},
  title = {Video-based beat-by-beat blood pressure monitoring via transfer deep-learning},
  journal = {Applied Intelligence},
  year = {2024},
  volume = {54},
  number = {6},
  pages = {4564--4584},
  doi = {10.1007/s10489-024-05354-9}
}
Kostenlos starten →