Monitoring blood pressure and cardiac function without positioning via a deep learning–assisted strain sensor array
Science Advances · 11.08.2023 · 9 (32)
DOI: 10.1126/sciadv.adh0615 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 11.08.2023. Verfasst von Shuo Li und 11 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Organic Optoelectronics and Molecular Engineering of the Ministry of Education, Department of Chemistry, Tsinghua University, Beiji…. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Deep Learning. Die Arbeit wurde bisher 225-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Continuous and reliable monitoring of blood pressure and cardiac function is of great importance for diagnosing and preventing cardiovascular diseases. However, existing cardiovascular monitoring approaches are bulky and costly, limiting their wide applications for early diagnosis. Here, we developed an intelligent blood pressure and cardiac function monitoring system based on a conformal and flexible strain sensor array and deep learning neural networks. The sensor has a variety of advantages, including high sensitivity, high linearity, fast response and recovery, and high isotropy. Experiments and simulation synergistically verified that the sensor array can acquire high-precise and feature-rich pulse waves from the wrist without precise positioning. By combining high-quality pulse waves with a well-trained deep learning model, we can monitor blood pressure and cardiac function parameters. As a proof of concept, we further constructed an intelligent wearable system for real-time and long-term monitoring of blood pressure and cardiac function, which may contribute to personalized health management, precise and early diagnosis, and remote treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of the Ministry of Education, Department of Chemistry, Tsinghua University, Beijing 100084, PR China.
- Department of Cardiovascular Disease, Peking University First Hospital, Beijing 100084, PR China.
ORCID-Profile: Shuo Li, Wei Ma, Yingying Zhang
Zitieren
APA
Li, S., Wang, H., Ma, W., Qiu, L., Xia, K., Zhang, Y., Lu, H., Zhu, M., Liang, X., Wu, X. E., Liang, H., & Zhang, Y. (2023). Monitoring blood pressure and cardiac function without positioning via a deep learning–assisted strain sensor array. Science Advances, 9(32). https://doi.org/10.1126/sciadv.adh0615
Vancouver
Li S, Wang H, Ma W, Qiu L, Xia K, Zhang Y, et al. Monitoring blood pressure and cardiac function without positioning via a deep learning–assisted strain sensor array. Science Advances. 2023;9(32). doi:10.1126/sciadv.adh0615
BibTeX
@article{Li2023,
author = {Li, Shuo and Wang, Haomin and Ma, Wei and Qiu, Lin and Xia, Kailun and Zhang, Yong and Lu, Haojie and Zhu, Mengjia and Liang, Xiaoping and Wu, Xun-En and Liang, Huarun and Zhang, Yingying},
title = {Monitoring blood pressure and cardiac function without positioning via a deep learning–assisted strain sensor array},
journal = {Science Advances},
year = {2023},
volume = {9},
number = {32},
doi = {10.1126/sciadv.adh0615}
}
EUVIMED