In Vitro and In Silico Characterization of the Aggregation of Thrombi on Textured Ventricular Cannula
Annals of Biomedical Engineering · 2024
DOI: 10.1007/s10439-024-03504-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2024. Verfasst von Wenxuan He und 6 weiteren Autor:innen. Beteiligte Einrichtung: Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, 14853, USA. Hauptthemen laut MEDLINE: Thrombosis, Computer Simulation, Cannula. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: NHLBI NIH HHS, National Heart, Lung, and Blood Institute.
Abstract (Originalsprache)
The unacceptably high stroke rate associated with HeartMate 3 ventricular assist device (VAD) without signs of adherent pump thrombosis is hypothesized to be the result of the emboli produced by the inflow cannula, that are ingested and ejected from the pump. This in vitro and numerical study aimed to emulate the surface features and supraphysiological shear of a ventricular cannula to provide insight into their effect on thrombogenesis. Human whole blood was perfused at calibrated flow rates in a microfluidic channel to achieve shear rates 1000-7500 s-1, comparable to that experienced on the cannula. The channel contained periodic teeth representative of the rough sintered surface of the HeartMate 3 cannula. The deposition of fluorescently labeled platelets was visualized in real time and analyzed with a custom entity tracking algorithm. Numerical simulations of a multi-constituent thrombosis model were performed to simulate laminar blood flow in the channel. The sustained growth of adherent platelets was observed in all shear conditions ( p < 0.05). However, the greatest deposition was observed at the lower shear rates. The location of deposition with respect to the microfluidic teeth was also found to vary with shear rate. This was confirmed by CFD simulation. The entity tracking algorithm revealed the spatial variation of instances of embolic events. This result suggests that the sintered surface of the ventricular cannula may engender unstable thrombi with a greater likelihood of embolization at supraphysiological shear rates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, 14853, USA.
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA.
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA. antaki@cornell.edu.
Förderung
- NHLBI NIH HHS
- National Heart, Lung, and Blood Institute
Zitieren
APA
He, W., Karmakar, A., Kang, J., Rowlands, G., Schirmacher, S., Méndez-Rojano, R., & Antaki, J. (2024). In Vitro and In Silico Characterization of the Aggregation of Thrombi on Textured Ventricular Cannula. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-024-03504-1
Vancouver
He W, Karmakar A, Kang J, Rowlands G, Schirmacher S, Méndez-Rojano R, et al. In Vitro and In Silico Characterization of the Aggregation of Thrombi on Textured Ventricular Cannula. Annals of Biomedical Engineering. 2024. doi:10.1007/s10439-024-03504-1
BibTeX
@article{He2024,
author = {He, Wenxuan and Karmakar, Abhishek and Kang, Junhyuk and Rowlands, Grant and Schirmacher, Samuel and Méndez-Rojano, Rodrigo and Antaki, James},
title = {In Vitro and In Silico Characterization of the Aggregation of Thrombi on Textured Ventricular Cannula},
journal = {Annals of Biomedical Engineering},
year = {2024},
doi = {10.1007/s10439-024-03504-1}
}
EUVIMED