EUVIMEDEUVIMED entdecken
Crossref

Effect of Nasal Inhalation on Drug Particle Deposition and Size Distribution in the Upper Airway: With Soft Mist Inhalers

Taha Sadeghi, Pedram Fatehi, Leila Pakzad

Annals of Biomedical Engineering · 2024

DOI: 10.1007/s10439-023-03423-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2024. Verfasst von Taha Sadeghi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Lakehead University, 955 Oliver Road, Thunder Bay, ON, P7B 5E1, Canada. Hauptthemen laut MEDLINE: Nebulizers and Vaporizers, Larynx. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Delivery of drugs to the lungs is commonly achieved using nasal and/or oral breathing-assisted techniques. The route of inhalation can substantially change the fate of inhaled droplets. The Respimat® Soft Mist™ Inhaler (SMI) is a commercially available efficient inhaler with 40-60% effectiveness. In the present study, we used computational fluid dynamics (CFD) with a custom setup to investigate the effect of a combined oral/nasal inhalation route on the SMI's regional droplet deposition, size distribution, and flow field. Our setup used a modified induction port (MIP) to mimic nasal inhalation inside the human respiratory tract. Six different oral/nasal flow rate ratios inside the MIP were applied (total flow rate of 30 l/min). An overall good agreement was achieved between simulation outcomes and in vitro results. Our results confirmed that the combined inhalation route affects the flow field, altering the MIP's droplet deposition and size distribution. The lowest depositional loss, mainly in the mouth area, was observed at oral/nasal flow rate ratios of O/N = 1 and O/N = 2 with 3% and 7.7% values, respectively. Droplets with a 2-5 µm diameter range showed the highest droplet mass inside the MIP at all combined flow rates. We observed less intense vortexes followed by a lower level of turbulent kinetic energy at the oral/nasal ratio of 1. Increasing the relative humidity (RH) at oral/nasal flow rate ratios of 0.07, 1, and 14 led to an increase in droplet deposition at the outlet of the MIP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nebulizers and VaporizersLarynxHumansAerosolsAdministration, InhalationLungParticle SizeEquipment Design

Stichwörter der Autor:innen

CFDCombined oral and nasal inhalationDeposition efficiencyDroplet diameterRelative humiditySMI

Substanzen

Aerosols

Autor:innen und Institutionen

  • Department of Chemical Engineering, Lakehead University, 955 Oliver Road, Thunder Bay, ON, P7B 5E1, Canada.
  • Department of Chemical Engineering, Lakehead University, 955 Oliver Road, Thunder Bay, ON, P7B 5E1, Canada. lpakzad@lakeheadu.ca.

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Sadeghi, T., Fatehi, P., & Pakzad, L. (2024). Effect of Nasal Inhalation on Drug Particle Deposition and Size Distribution in the Upper Airway: With Soft Mist Inhalers. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-023-03423-7

Vancouver

Sadeghi T, Fatehi P, Pakzad L. Effect of Nasal Inhalation on Drug Particle Deposition and Size Distribution in the Upper Airway: With Soft Mist Inhalers. Annals of Biomedical Engineering. 2024. doi:10.1007/s10439-023-03423-7

BibTeX
@article{Sadeghi2024,
  author = {Sadeghi, Taha and Fatehi, Pedram and Pakzad, Leila},
  title = {Effect of Nasal Inhalation on Drug Particle Deposition and Size Distribution in the Upper Airway: With Soft Mist Inhalers},
  journal = {Annals of Biomedical Engineering},
  year = {2024},
  doi = {10.1007/s10439-023-03423-7}
}
Kostenlos starten →