Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid–Structure Interaction Analysis
Annals of Biomedical Engineering · 2024
DOI: 10.1007/s10439-023-03419-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2024. Verfasst von David Oks und 6 weiteren Autor:innen. Beteiligte Einrichtung: Barcelona Supercomputing Center, Computer Applications in Science and Engineering, Barcelona, Spain. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Thrombosis, Aortic Valve Stenosis, Heart Valve Prosthesis. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, HORIZON EUROPE Marie Sklodowska-Curie Actions, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
TAVR has emerged as a standard approach for treating severe aortic stenosis patients. However, it is associated with several clinical complications, including subclinical leaflet thrombosis characterized by Hypoattenuated Leaflet Thickening (HALT). A rigorous analysis of TAVR device thrombogenicity considering anatomical variations is essential for estimating this risk. Clinicians use the Sinotubular Junction (STJ) diameter for TAVR sizing, but there is a paucity of research on its influence on TAVR devices thrombogenicity. A Medtronic Evolut® TAVR device was deployed in three patient models with varying STJ diameters (26, 30, and 34 mm) to evaluate its impact on post-deployment hemodynamics and thrombogenicity, employing a novel computational framework combining prosthesis deployment and fluid-structure interaction analysis. The 30 mm STJ patient case exhibited the best hemodynamic performance: 5.94 mmHg mean transvalvular pressure gradient (TPG), 2.64 cm2 mean geometric orifice area (GOA), and the lowest mean residence time (TR)-indicating a reduced thrombogenic risk; 26 mm STJ exhibited a 10 % reduction in GOA and a 35% increase in mean TPG compared to the 30 mm STJ; 34 mm STJ depicted hemodynamics comparable to the 30 mm STJ, but with a 6% increase in TR and elevated platelet stress accumulation. A smaller STJ size impairs adequate expansion of the TAVR stent, which may lead to suboptimal hemodynamic performance. Conversely, a larger STJ size marginally enhances the hemodynamic performance but increases the risk of TAVR leaflet thrombosis. Such analysis can aid pre-procedural planning and minimize the risk of TAVR leaflet thrombosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Barcelona Supercomputing Center, Computer Applications in Science and Engineering, Barcelona, Spain.
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8084, USA.
- ELEM Biotech SL, Barcelona, Spain.
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8084, USA. danny.bluestein@stonybrook.edu.
Förderung
- NIBIB NIH HHS
- HORIZON EUROPE Marie Sklodowska-Curie Actions
- National Institute of Biomedical Imaging and Bioengineering
- CompBioMed2
Zitieren
APA
Oks, D., Reza, S., Vázquez, M., Houzeaux, G., Kovarovic, B., Samaniego, C., & Bluestein, D. (2024). Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid–Structure Interaction Analysis. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-023-03419-3
Vancouver
Oks D, Reza S, Vázquez M, Houzeaux G, Kovarovic B, Samaniego C, et al. Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid–Structure Interaction Analysis. Annals of Biomedical Engineering. 2024. doi:10.1007/s10439-023-03419-3
BibTeX
@article{Oks2024,
author = {Oks, David and Reza, Symon and Vázquez, Mariano and Houzeaux, Guillaume and Kovarovic, Brandon and Samaniego, Cristóbal and Bluestein, Danny},
title = {Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid–Structure Interaction Analysis},
journal = {Annals of Biomedical Engineering},
year = {2024},
doi = {10.1007/s10439-023-03419-3}
}
EUVIMED