Comparison of visual performance between three enhanced monofocal intraocular lenses under different refractive targets
Japanese Journal of Ophthalmology · 2026-07 · 70 (4) · 813-819
DOI: 10.1007/s10384-026-01339-y ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Japanese Journal of Ophthalmology, online erschienen am 04.03.2026. Verfasst von Hisaharu Suzuki und 1 weiteren Autor:innen. Beteiligte Einrichtung: Zengyo Suzuki Eye Clinic, 1-22-11 Zengyo, Fujisawa-shi, Kanagawa, 251-0871, Japan. s5054@nms.ac.jp. Hauptthemen laut MEDLINE: Visual Acuity, Contrast Sensitivity, Lenses, Intraocular, Refraction, Ocular. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To compare the monocular uncorrected visual acuity (UCVA) and contrast sensitivity (CS) of three enhanced monofocal intraocular lenses (IOLs) under emmetropic and mild myopic refractive targets. STUDY DESIGN: Single-center retrospective observational study. METHODS: Among 198 patients (244 eyes) who underwent uneventful cataract surgery with enhanced monofocal IOL implantation (Tecnis Eyhance [DIB00V, E group], Vivinex Impress [XY1-EM, I group], NIDEK NSP-3 [N group]) with emmetropia or mild myopia (-1.00D), refractive targets, monocular UCVA at six different distances (5, 1, 70, 50, 40, and 30 cm) and CS with and without glare were assessed 1 month postoperatively and compared using the Kruskal-Wallis test followed by the Steel-Dwass post-hoc test. RESULTS: In the emmetropic group, UCVA for all IOLs achieved ≤ 0.2 logMAR from 5 m to 50 cm, with significantly better UCVA at 5 m in the E than I group (p = 0.0300) and at 50 cm in the I than N group (p = 0.0242). For mild myopia, the N group achieved better UCVA at 5 m (p = 0.0066), the I group showed superior near-visual acuity at 30 cm than the E group (p = 0.0457), and UCVA for all IOLs achieved ≤ 0.2 logMAR from 1 m to 40 cm, with the highest CS at 6, 12, and 18 cycles per degree, with and without glare, in the E group. These findings suggest that combining enhanced monofocal IOLs with mild myopic targeting (-1.0 D) may optimize functional vision for everyday activities, particularly in older adults who rely on safe intermediate and near vision in daily life. CONCLUSIONS: All IOLs showed good UCVA. The E, I, and N groups demonstrated balanced visual performance, with superior contrast sensitivity, superior near-to-intermediate vision, and superior distance vision, respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Zengyo Suzuki Eye Clinic, 1-22-11 Zengyo, Fujisawa-shi, Kanagawa, 251-0871, Japan. s5054@nms.ac.jp.
- Zengyo Suzuki Eye Clinic, 1-22-11 Zengyo, Fujisawa-shi, Kanagawa, 251-0871, Japan.
Zitieren
APA
Suzuki, H., & Nishiyama, M. (2026). Comparison of visual performance between three enhanced monofocal intraocular lenses under different refractive targets. Japanese Journal of Ophthalmology, 70(4), 813-819. https://doi.org/10.1007/s10384-026-01339-y
Vancouver
Suzuki H, Nishiyama M. Comparison of visual performance between three enhanced monofocal intraocular lenses under different refractive targets. Japanese Journal of Ophthalmology. 2026;70(4):813-819. doi:10.1007/s10384-026-01339-y
BibTeX
@article{Suzuki2026,
author = {Suzuki, Hisaharu and Nishiyama, Miho},
title = {Comparison of visual performance between three enhanced monofocal intraocular lenses under different refractive targets},
journal = {Japanese Journal of Ophthalmology},
year = {2026},
volume = {70},
number = {4},
pages = {813--819},
doi = {10.1007/s10384-026-01339-y}
}
EUVIMED