The Intraocular Lens Tilt and Decentration of Two Different Hydrophobic Aspheric Monofocal Intraocular Lenses
romanian journal of ophthalmology · 2025
DOI: 10.22336/rjo.2025.57 ↗Kurz gefasst
Fachartikel in der Zeitschrift romanian journal of ophthalmology, 2025. Verfasst von Yasin Sakir Goker und 3 weiteren Autor:innen. Beteiligte Einrichtung: Goker Retina and Eye Clinic, Ankara, Turkey. Hauptthemen laut MEDLINE: Lenses, Intraocular, Visual Acuity, Lens Implantation, Intraocular, Phacoemulsification. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
To evaluate the clinical performance of two monofocal aspheric intraocular lenses (IOLs) to determine their position in the capsular bag after implantation.
Methods
This retrospective study collates data from the medical records of patients who underwent cataract surgery and were implanted with two different hydrophobic aspheric monofocal IOLs. A total of 6 visit data were considered in the study, out of which four follow-up visits were on day 1, 7, 30, and 180 postoperatively. The investigational variables included IOL tilt and decentration, uncorrected and best corrected visual acuity (UCVA and BCVA), contrast sensitivity, manifest refraction, intraocular pressure, and posterior capsule opacification.
Results
A total of 85 subjects' medical records were screened. Nineteen subjects discontinued the study due to loss to follow-up. Thirty subjects' medical records were enrolled in the IOL 1 arm, and 36 subjects' medical records were enrolled in the IOL 2 arm. There were no statistically significant differences in vertical and horizontal IOL tilt and decentration results between IOL 1 arm and IOL 2 arm. Within-group analysis revealed a significant difference in BCVA at all visits from baseline for both the IOL 1 and IOL 2 arms. In the between-group analysis, there were no significant differences in BCVA at any visit between the IOL 1 and IOL 2 arms.
Discussion
Tilt and decentration of IOL may occur secondary to complicated cataract surgery or following uneventful phacoemulsification. IOL tilt up to 2-3 degrees and decentration of 0.2-0.3 mm are common and not clinically significant. Larger amounts of decentration and tilt deteriorate the optical performance of the IOLs, subsequently affecting the patients' vision.
Conclusion
IOL vertical and horizontal tilt and decentration found in the current study are within the limits reported in the literature. The position of these two lenses in the capsular bag remains very stable at day 180 after implantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Goker Retina and Eye Clinic, Ankara, Turkey.
- Department Of Ophthalmology, Okan University, Istanbul, Turkey.
- Ideal Eye Center, Kayseri, Turkey.
- Tatvan State Hospital, Bitlis, Turkey.
Zitieren
APA
Goker, Y. S., Ozates, S., Koc, M., & Ateşoğlu, H. İ. (2025). The Intraocular Lens Tilt and Decentration of Two Different Hydrophobic Aspheric Monofocal Intraocular Lenses. romanian journal of ophthalmology. https://doi.org/10.22336/rjo.2025.57
Vancouver
Goker YS, Ozates S, Koc M, Ateşoğlu Hİ. The Intraocular Lens Tilt and Decentration of Two Different Hydrophobic Aspheric Monofocal Intraocular Lenses. romanian journal of ophthalmology. 2025. doi:10.22336/rjo.2025.57
BibTeX
@article{Goker2025,
author = {Goker, Yasin Sakir and Ozates, Serdar and Koc, Mustafa and Ateşoğlu, Halil İbrahim},
title = {The Intraocular Lens Tilt and Decentration of Two Different Hydrophobic Aspheric Monofocal Intraocular Lenses},
journal = {romanian journal of ophthalmology},
year = {2025},
doi = {10.22336/rjo.2025.57}
}
EUVIMED