EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical performance of a hydrophobic acrylic toric intraocular lens with a double C-loop haptics in Japanese patients

Yosai Mori, Kazunori Miyata, Takashi Kojima, Kazuo Ichikawa, Yoshifumi Fujita, Takuya Shiba, Hiroko Bissen-Miyajima

Japanese Journal of Ophthalmology · 2025

DOI: 10.1007/s10384-025-01274-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Ophthalmology, 2025. Verfasst von Yosai Mori und 6 weiteren Autor:innen. Beteiligte Einrichtung: Miyata Eye Hospital, 6-3 Kurahara-cho, Miyakonojo, Miyazaki, 885-0051, Japan. mori@miyata-med.ne.jp. Hauptthemen laut MEDLINE: Lenses, Intraocular, Visual Acuity, Astigmatism, Refraction, Ocular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the clinical performance of a hydrophobic acrylic toric intraocular lens (IOL) with double C-loop haptics in a Japanese population with cataracts. Study design Prospective Methods The PODEYE TORIC IOL (POD T 49P) was implanted in 58 eyes from 42 patients diagnosed with bilateral cataracts with corneal astigmatism. Thirty-one eyes received IOLs with cylinder powers of 1.50 to 6.00 D (group A), and 27 eyes received IOLs with 1.00 D cylinder (group B). Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and refractive cylinder were examined postoperatively. The primary endpoints, which were the non-inferiority of UDVA in group A and superiority of the refractive cylinder in group B, were examined and compared with relevant previous data.

Results

In group A, the mean preoperative corneal astigmatism was 1.87±1.01 D and postoperative logMAR UDVA and CDVA were -0.023±0.110 and -0.102±0.079, respectively. There were 23 eyes (74.2%) with UDVA of 0.0 logMAR or better, while the refractive cylinder was - 0.39±0.39 D. In group B, the preoperative corneal astigmatism of 0.73±0.22 D and postoperative logMAR UDVA and CDVA were -0.074±0.091 and -0.096±0.075, respectively; 23 eyes (85.2%) obtained a UDVA of 0.0 logMAR or better. The postoperative refractive cylinder was -0.16±0.23D. The non-inferiority of UDVA in group A and the superiority of the refractive cylinder in group B were verified with previous data.

Conclusion

The PODEYE TORIC IOL with 1.00–6.00 D cylinder powers and double C-loop haptics effectively corrected corneal astigmatism in Japanese patients after cataract surgery. Trial registration number NCT04699266 (Clinicaltrials.gov)

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularVisual AcuityAstigmatismRefraction, OcularLens Implantation, IntraocularAcrylic ResinsPhacoemulsificationPseudophakiaHumansProspective StudiesMaleFemaleAgedProsthesis DesignMiddle AgedJapanHydrophobic and Hydrophilic InteractionsFollow-Up StudiesAged, 80 and overCataractTreatment OutcomeEast Asian People

Stichwörter der Autor:innen

AstigmatismCataractDouble C-loopIntraocular lensMonofocal toric

Substanzen

Acrylic Resins

Autor:innen und Institutionen

  • Miyata Eye Hospital, 6-3 Kurahara-cho, Miyakonojo, Miyazaki, 885-0051, Japan. mori@miyata-med.ne.jp.
  • Miyata Eye Hospital, 6-3 Kurahara-cho, Miyakonojo, Miyazaki, 885-0051, Japan.
  • Chukyo Eye Clinic, Nagoya, Aichi, Japan.
  • Fujita Eye Clinic, Tokushima, Tokushima, Japan.
  • Roppongi Shiba Eye Clinic, Minato-ku, Tokyo, Japan.
  • Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Chiyada-ku, Tokyo, Japan.

Zitieren

APA

Mori, Y., Miyata, K., Kojima, T., Ichikawa, K., Fujita, Y., Shiba, T., & Bissen-Miyajima, H. (2025). Clinical performance of a hydrophobic acrylic toric intraocular lens with a double C-loop haptics in Japanese patients. Japanese Journal of Ophthalmology. https://doi.org/10.1007/s10384-025-01274-4

Vancouver

Mori Y, Miyata K, Kojima T, Ichikawa K, Fujita Y, Shiba T, et al. Clinical performance of a hydrophobic acrylic toric intraocular lens with a double C-loop haptics in Japanese patients. Japanese Journal of Ophthalmology. 2025. doi:10.1007/s10384-025-01274-4

BibTeX
@article{Mori2025,
  author = {Mori, Yosai and Miyata, Kazunori and Kojima, Takashi and Ichikawa, Kazuo and Fujita, Yoshifumi and Shiba, Takuya and Bissen-Miyajima, Hiroko},
  title = {Clinical performance of a hydrophobic acrylic toric intraocular lens with a double C-loop haptics in Japanese patients},
  journal = {Japanese Journal of Ophthalmology},
  year = {2025},
  doi = {10.1007/s10384-025-01274-4}
}
Kostenlos starten →