EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

One-year rotational stability and refractive outcomes of the Acriva BB T UDM 611 toric ıntraocular lens: A prospective study

Merve Inanc Tekin, Kemal Tekin, Ozge Uysal, Necip Kara, Pinar Ozdal

Indian Journal of Ophthalmology · 2026-05 · 74 (Suppl 1) · S74-S79

DOI: 10.4103/ijo.ijo_1884_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 30.04.2026. Verfasst von Merve Inanc Tekin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey. Hauptthemen laut MEDLINE: Visual Acuity, Lenses, Intraocular, Refraction, Ocular, Astigmatism. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the 1-year clinical outcomes of the Acriva BB T UDM 611 toric intraocular lens (IOL) following cataract surgery in patients with preoperative corneal astigmatism, focusing on rotational stability, refractive efficacy, visual acuity, contrast sensitivity (CS), and safety.

Methods

This prospective longitudinal study included 39 eyes of 32 patients with age-related cataract and regular corneal astigmatism ≥1.0 diopter who underwent phacoemulsification and toric IOL implantation at a tertiary eye care center. Preoperative and postoperative assessments included uncorrected (UDVA) and corrected distance visual acuity (CDVA), corneal and refractive astigmatism, IOL rotation, decentration, and tilt. The CSV-1000 test was used to measure CS at 2.5 m under photopic, mesopic, and mesopic with glare conditions. Adverse events were recorded.

Results

The mean logMAR UDVA improved significantly from 0.95± 0.39 preoperatively to 0.06 ± 0.10 at 1 year (p < 0.001). The refractive cylinder decreased from -2.17 ± 1.75 D to -0.21 ± 0.32 D (p < 0.001). The mean IOL rotation was 1.61° ±2.35°, with 89.7% of eyes within ±5° and all within ±10° of the intended axis. No IOL repositioning was required. No patients reported disturbing visual phenomena, and no vision-threatening complications occurred during the follow-up.

Conclusions

The Acriva BB T UDM 611 toric IOL demonstrated excellent rotational stability, significant refractive accuracy, and favorable safety and CS outcomes at 1 year postoperatively. These results support its efficacy in correcting pre-existing corneal astigmatism in cataract patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityLenses, IntraocularRefraction, OcularAstigmatismPhacoemulsificationLens Implantation, IntraocularCataractHumansProspective StudiesFemaleMaleFollow-Up StudiesProsthesis DesignAgedContrast SensitivityMiddle AgedTime FactorsRotationTreatment Outcome

Stichwörter der Autor:innen

Astigmatism correctioncataract surgerycontrast sensitivityrotational stabilitytoric intraocular lensvisual acuity

Autor:innen und Institutionen

  • Department of Ophthalmology, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey.
  • Department of Ophthalmology, Gaziantep University, Gaziantep, Turkey.

Zitieren

APA

Tekin, M. I., Tekin, K., Uysal, O., Kara, N., & Ozdal, P. (2026). One-year rotational stability and refractive outcomes of the Acriva BB T UDM 611 toric ıntraocular lens: A prospective study. Indian Journal of Ophthalmology, 74(Suppl 1), S74-S79. https://doi.org/10.4103/ijo.ijo_1884_25

Vancouver

Tekin MI, Tekin K, Uysal O, Kara N, Ozdal P. One-year rotational stability and refractive outcomes of the Acriva BB T UDM 611 toric ıntraocular lens: A prospective study. Indian Journal of Ophthalmology. 2026;74(Suppl 1):S74-S79. doi:10.4103/ijo.ijo_1884_25

BibTeX
@article{Tekin2026,
  author = {Tekin, Merve Inanc and Tekin, Kemal and Uysal, Ozge and Kara, Necip and Ozdal, Pinar},
  title = {One-year rotational stability and refractive outcomes of the Acriva BB T UDM 611 toric ıntraocular lens: A prospective study},
  journal = {Indian Journal of Ophthalmology},
  year = {2026},
  volume = {74},
  number = {Suppl 1},
  pages = {S74--S79},
  doi = {10.4103/ijo.ijo_1884_25}
}
Kostenlos starten →