Optimal cardiac phase selection using motion-sensitive cine imaging improves T2w-STIR image quality in cardiac MRI
Magnetic Resonance Materials in Physics, Biology and Medicine · 11.07.2026
DOI: 10.1007/s10334-026-01391-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 11.07.2026. Verfasst von Yoshihiko Tachikawa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiological Technology, Department of Medical Technology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan. yoshi…. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Cardiac T2-weighted short-tau inversion recovery (T2w-STIR) is highly susceptible to myocardial motion, and acquisition at inappropriate cardiac phases can cause myocardial signal loss and inhomogeneity. This study investigated whether cardiac phase selection based on motion-sensitive (MoSe) cine imaging improves T2w-STIR image quality compared with conventional ECG-synchronized acquisition at the longest trigger delay corresponding to end-diastole. MATERIALS AND METHODS: Twelve healthy volunteers underwent 1.5T cardiac MRI. MoSe cine imaging with ECG and peripheral pulse unit (PPU) synchronization was used to visually identify phases with minimal myocardial motion. Short-axis T2w-STIR images were acquired at Conv[ECG-l] (longest ECG trigger delay at end-diastole), MoSe[ECG-S] (MoSe-determined systolic phase with ECG), and MoSe[PPU-D] (MoSe-determined diastolic phase with PPU). Quantitative assessments were myocardium-to-spleen ratio (MSR) and inter- and intra-slice MSR coefficient of variation (CV). Overall image quality was scored on a 4-point scale. RESULTS: MoSe[PPU-D] yielded higher MSR and lower inter- and intra-slice CVs than Conv[ECG-l] (p < 0.05), and higher MSR and lower intra-slice CV than MoSe[ECG-S] (p < 0.05). Qualitative scores were higher for MoSe[PPU-D] than for Conv[ECG-l] and MoSe[ECG-S] (p < 0.05). CONCLUSION: Cardiac T2w-STIR images acquired at the MoSe-identified optimal diastolic phase with PPU synchronization provide superior image quality compared with conventional ECG-synchronized approach.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Radiological Technology, Department of Medical Technology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan. yoshihiko-tachikawa@karatsu.jrc.or.jp.
- Graduate School of Health Sciences, Kumamoto University, Kumamoto, Japan. yoshihiko-tachikawa@karatsu.jrc.or.jp.
- Division of Radiological Technology, Department of Radiology, Nihon University Hospital, Tokyo, Japan.
- Division of Radiological Technology, Department of Medical Technology, Karatsu Red Cross Hospital, 2430 Watada, Karatsu, Saga, 847-8588, Japan.
- Department of Medical Imaging Technology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan.
Zitieren
APA
Tachikawa, Y., Ando, C., Ishikawa, R., & Fujiwara, Y. (2026). Optimal cardiac phase selection using motion-sensitive cine imaging improves T2w-STIR image quality in cardiac MRI. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-026-01391-2
Vancouver
Tachikawa Y, Ando C, Ishikawa R, Fujiwara Y. Optimal cardiac phase selection using motion-sensitive cine imaging improves T2w-STIR image quality in cardiac MRI. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026. doi:10.1007/s10334-026-01391-2
BibTeX
@article{Tachikawa2026,
author = {Tachikawa, Yoshihiko and Ando, Chisato and Ishikawa, Risa and Fujiwara, Yasuhiro},
title = {Optimal cardiac phase selection using motion-sensitive cine imaging improves T2w-STIR image quality in cardiac MRI},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2026},
doi = {10.1007/s10334-026-01391-2}
}
EUVIMED