Single‐heartbeat cardiac cine imaging via jointly regularized nonrigid motion‐corrected reconstruction
NMR in Biomedicine · 2023-09 · 36 (9)
DOI: 10.1002/nbm.4942 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 13.05.2023. Verfasst von Gastao Cruz und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, British Heart Foundation, Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
The aim of the current study was to develop a novel approach for 2D breath‐hold cardiac cine imaging from a single heartbeat, by combining cardiac motion‐corrected reconstructions and nonrigidly aligned patch‐based regularization. Conventional cardiac cine imaging is obtained via motion‐resolved reconstructions of data acquired over multiple heartbeats. Here, we achieve single‐heartbeat cine imaging by incorporating nonrigid cardiac motion correction into the reconstruction of each cardiac phase, in conjunction with a motion‐aligned patch‐based regularization. The proposed Motion‐Corrected CINE (MC‐CINE) incorporates all acquired data into the reconstruction of each (motion‐corrected) cardiac phase, resulting in a better posed problem than motion‐resolved approaches. MC‐CINE was compared with iterative sensitivity encoding (itSENSE) and Extra‐Dimensional Golden Angle Radial Sparse Parallel (XD‐GRASP) in 14 healthy subjects in terms of image sharpness, reader scoring (range: 1–5) and reader ranking (range: 1–9) of image quality, and single‐slice left ventricular assessment. MC‐CINE was significantly superior to both itSENSE and XD‐GRASP using 20 heartbeats, two heartbeats, and one heartbeat. Iterative SENSE, XD‐GRASP, and MC‐CINE achieved a sharpness of 74%, 74%, and 82% using 20 heartbeats, and 53%, 66%, and 82% with one heartbeat, respectively. The corresponding results for reader scoring were 4.0, 4.7, and 4.9 with 20 heartbeats, and 1.1, 3.0, and 3.9 with one heartbeat. The corresponding results for reader ranking were 5.3, 7.3, and 8.6 with 20 heartbeats, and 1.0, 3.2, and 5.4 with one heartbeat. MC‐CINE using a single heartbeat presented nonsignificant differences in image quality to itSENSE with 20 heartbeats. MC‐CINE and XD‐GRASP at one heartbeat both presented a nonsignificant negative bias of less than 2% in ejection fraction relative to the reference itSENSE. It was concluded that the proposed MC‐CINE significantly improves image quality relative to itSENSE and XD‐GRASP, enabling 2D cine from a single heartbeat.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Department of Computing, Imperial College London, London, UK.
- Institute for Artificial Intelligence and Informatics in Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
- Medical Image and Data Analysis, Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany.
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.
- Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile.
ORCID-Profile: Gastao Cruz
Förderung
- Wellcome Trust
- British Heart Foundation
- Engineering and Physical Sciences Research Council
- Fondo Nacional de Desarrollo Científico, Tecnológico y de Innovación Tecnológica
- Núcleo Milenio Información y Coordinación en Redes, ICR
- Centre For Medical Engineering, King’s College London
Zitieren
APA
Cruz, G., Hammernik, K., Kuestner, T., Velasco, C., Hua, A., Ismail, T. F., Rueckert, D., Botnar, R. M., & Prieto, C. (2023). Single‐heartbeat cardiac cine imaging via jointly regularized nonrigid motion‐corrected reconstruction. NMR in Biomedicine, 36(9). https://doi.org/10.1002/nbm.4942
Vancouver
Cruz G, Hammernik K, Kuestner T, Velasco C, Hua A, Ismail TF, et al. Single‐heartbeat cardiac cine imaging via jointly regularized nonrigid motion‐corrected reconstruction. NMR in Biomedicine. 2023;36(9). doi:10.1002/nbm.4942
BibTeX
@article{Cruz2023,
author = {Cruz, Gastao and Hammernik, Kerstin and Kuestner, Thomas and Velasco, Carlos and Hua, Alina and Ismail, Tevfik Fehmi and Rueckert, Daniel and Botnar, Rene Michael and Prieto, Claudia},
title = {Single‐heartbeat cardiac cine imaging via jointly regularized nonrigid motion‐corrected reconstruction},
journal = {NMR in Biomedicine},
year = {2023},
volume = {36},
number = {9},
doi = {10.1002/nbm.4942}
}
EUVIMED