Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling
Magnetic Resonance Materials in Physics, Biology and Medicine · 2018-02 · 31 (1) · 19-31
DOI: 10.1007/s10334-017-0624-1 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 26.05.2017. Verfasst von Jens Wetzl und 7 weiteren Autor:innen. Beteiligte Einrichtung: Pattern Recognition Lab, Department of Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstr. 3, 91058, Erlangen, Germany. …. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: Our objectives were to evaluate a single-breath-hold approach for Cartesian 3-D CINE imaging of the left ventricle with a nearly isotropic resolution of [Formula: see text] and a breath-hold duration of [Formula: see text]19 s against a standard stack of 2-D CINE slices acquired in multiple breath-holds. Validation is performed with data sets from ten healthy volunteers. MATERIALS AND METHODS: A Cartesian sampling pattern based on the spiral phyllotaxis and a compressed sensing reconstruction method are proposed to allow 3-D CINE imaging with high acceleration factors. The fully integrated reconstruction uses multiple graphics processing units to speed up the reconstruction. The 2-D CINE and 3-D CINE are compared based on ventricular function parameters, contrast-to-noise ratio and edge sharpness measurements. RESULTS: Visual comparisons of corresponding short-axis slices of 2-D and 3-D CINE show an excellent match, while 3-D CINE also allows reformatting to other orientations. Ventricular function parameters do not significantly differ from values based on 2-D CINE imaging. Reconstruction times are below 4 min. CONCLUSION: We demonstrate single-breath-hold 3-D CINE imaging in volunteers and three example patient cases, which features fast reconstruction and allows reformatting to arbitrary orientations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pattern Recognition Lab, Department of Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstr. 3, 91058, Erlangen, Germany. jens.wetzl@fau.de.
- Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany. jens.wetzl@fau.de.
- Siemens Healthcare GmbH, Erlangen, Germany.
- Department of Cardiovascular Imaging, CHU Lille and Univ. Lille, 59000, Lille, France.
- Pattern Recognition Lab, Department of Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstr. 3, 91058, Erlangen, Germany.
- Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Zitieren
APA
Wetzl, J., Schmidt, M., Pontana, F., Longère, B., Lugauer, F., Maier, A., Hornegger, J., & Forman, C. (2018). Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling. Magnetic Resonance Materials in Physics, Biology and Medicine, 31(1), 19-31. https://doi.org/10.1007/s10334-017-0624-1
Vancouver
Wetzl J, Schmidt M, Pontana F, Longère B, Lugauer F, Maier A, et al. Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling. Magnetic Resonance Materials in Physics, Biology and Medicine. 2018;31(1):19-31. doi:10.1007/s10334-017-0624-1
BibTeX
@article{Wetzl2018,
author = {Wetzl, Jens and Schmidt, Michaela and Pontana, François and Longère, Benjamin and Lugauer, Felix and Maier, Andreas and Hornegger, Joachim and Forman, Christoph},
title = {Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2018},
volume = {31},
number = {1},
pages = {19--31},
doi = {10.1007/s10334-017-0624-1}
}
EUVIMED