Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy
Journal of Imaging Informatics in Medicine · 2024
DOI: 10.1007/s10278-024-01312-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, 2024. Verfasst von Yuhei Koike und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan. koikeyuh@hirakata.kmu.ac.jp. Hauptthemen laut MEDLINE: Deep Learning, Prostatic Neoplasms, Cone-Beam Computed Tomography, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Cone-beam computed tomography (CBCT) is widely utilized in image-guided radiation therapy; however, its image quality is poor compared to planning CT (pCT), thus restricting its utility for adaptive radiotherapy (ART). Our objective was to enhance CBCT image quality utilizing a transformer-based deep learning model, SwinUNETR, which we compared with a conventional convolutional neural network (CNN) model, U-net. This retrospective study involved 260 patients undergoing prostate radiotherapy, with 245 patients used for training and 15 patients reserved as an independent hold-out test dataset. Employing a CycleGAN framework, we generated synthetic CT (sCT) images from CBCT images, employing SwinUNETR and U-net as generators. We evaluated sCT image quality and assessed its dosimetric impact for photon therapy through gamma analysis and dose-volume histogram (DVH) comparisons. The mean absolute error values for the CT numbers, calculated using all voxels within the patient's body contour and taking the pCT images as a reference, were 84.07, 73.49, and 64.69 Hounsfield units for CBCT, U-net, and SwinUNETR images, respectively. Gamma analysis revealed superior agreement between the dose on the pCT images and on the SwinUNETR-based sCT plans compared to those based on U-net. DVH parameters calculated on the SwinUNETR-based sCT deviated by < 1% from those in pCT plans. Our study showed that, compared to the U-net model, SwinUNETR could proficiently generate more precise sCT images from CBCT images, facilitating more accurate dose calculations. This study demonstrates the superiority of transformer-based models over conventional CNN-based approaches for CBCT-to-CT translation, contributing to the advancement of image synthesis techniques in ART.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan. koikeyuh@hirakata.kmu.ac.jp.
- Division of Radiation Oncology, Kansai Medical University Hospital, 2-3-1 Shinmachi, Hirakata, Osaka, 573-1191, Japan. koikeyuh@hirakata.kmu.ac.jp.
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
- Division of Radiation Oncology, Kansai Medical University Hospital, 2-3-1 Shinmachi, Hirakata, Osaka, 573-1191, Japan.
- Division of Radiation Oncology, Kansai Medical University Medical Center, 10-15 Fumizono-Cho, Moriguchi, Osaka, 570-8507, Japan.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Koike, Y., Takegawa, H., Anetai, Y., Nakamura, S., Yoshida, K., Yoshida, A., Yui, M., Hirota, K., Ueda, K., & Tanigawa, N. (2024). Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-024-01312-6
Vancouver
Koike Y, Takegawa H, Anetai Y, Nakamura S, Yoshida K, Yoshida A, et al. Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy. Journal of Imaging Informatics in Medicine. 2024. doi:10.1007/s10278-024-01312-6
BibTeX
@article{Koike2024,
author = {Koike, Yuhei and Takegawa, Hideki and Anetai, Yusuke and Nakamura, Satoaki and Yoshida, Ken and Yoshida, Asami and Yui, Midori and Hirota, Kazuki and Ueda, Kenichi and Tanigawa, Noboru},
title = {Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy},
journal = {Journal of Imaging Informatics in Medicine},
year = {2024},
doi = {10.1007/s10278-024-01312-6}
}