Open Access

Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy

Yuhei Koike, Hideki Takegawa, Yusuke Anetai, Satoaki Nakamura, Ken Yoshida, Asami Yoshida, Midori Yui, Kazuki Hirota, Kenichi Ueda, Noboru Tanigawa

Journal of Imaging Informatics in Medicine · 2024

DOI: 10.1007/s10278-024-01312-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Imaging Informatics in Medicine, 2024. Verfasst von Yuhei Koike und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan. koikeyuh@hirakata.kmu.ac.jp. Hauptthemen laut MEDLINE: Deep Learning, Prostatic Neoplasms, Cone-Beam Computed Tomography, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cone-beam computed tomography (CBCT) is widely utilized in image-guided radiation therapy; however, its image quality is poor compared to planning CT (pCT), thus restricting its utility for adaptive radiotherapy (ART). Our objective was to enhance CBCT image quality utilizing a transformer-based deep learning model, SwinUNETR, which we compared with a conventional convolutional neural network (CNN) model, U-net. This retrospective study involved 260 patients undergoing prostate radiotherapy, with 245 patients used for training and 15 patients reserved as an independent hold-out test dataset. Employing a CycleGAN framework, we generated synthetic CT (sCT) images from CBCT images, employing SwinUNETR and U-net as generators. We evaluated sCT image quality and assessed its dosimetric impact for photon therapy through gamma analysis and dose-volume histogram (DVH) comparisons. The mean absolute error values for the CT numbers, calculated using all voxels within the patient's body contour and taking the pCT images as a reference, were 84.07, 73.49, and 64.69 Hounsfield units for CBCT, U-net, and SwinUNETR images, respectively. Gamma analysis revealed superior agreement between the dose on the pCT images and on the SwinUNETR-based sCT plans compared to those based on U-net. DVH parameters calculated on the SwinUNETR-based sCT deviated by < 1% from those in pCT plans. Our study showed that, compared to the U-net model, SwinUNETR could proficiently generate more precise sCT images from CBCT images, facilitating more accurate dose calculations. This study demonstrates the superiority of transformer-based models over conventional CNN-based approaches for CBCT-to-CT translation, contributing to the advancement of image synthesis techniques in ART.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningProstatic NeoplasmsCone-Beam Computed TomographyRadiotherapy, Image-GuidedHumansMaleRetrospective StudiesRadiotherapy Planning, Computer-AssistedNeural Networks, ComputerRadiotherapy Dosage

Stichwörter der Autor:innen

Adaptive radiotherapyCBCTDeep learningProstate cancerTransformer

Autor:innen und Institutionen

  • Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan. koikeyuh@hirakata.kmu.ac.jp.
  • Division of Radiation Oncology, Kansai Medical University Hospital, 2-3-1 Shinmachi, Hirakata, Osaka, 573-1191, Japan. koikeyuh@hirakata.kmu.ac.jp.
  • Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
  • Division of Radiation Oncology, Kansai Medical University Hospital, 2-3-1 Shinmachi, Hirakata, Osaka, 573-1191, Japan.
  • Division of Radiation Oncology, Kansai Medical University Medical Center, 10-15 Fumizono-Cho, Moriguchi, Osaka, 570-8507, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Koike, Y., Takegawa, H., Anetai, Y., Nakamura, S., Yoshida, K., Yoshida, A., Yui, M., Hirota, K., Ueda, K., & Tanigawa, N. (2024). Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-024-01312-6

Vancouver

Koike Y, Takegawa H, Anetai Y, Nakamura S, Yoshida K, Yoshida A, et al. Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy. Journal of Imaging Informatics in Medicine. 2024. doi:10.1007/s10278-024-01312-6

BibTeX
@article{Koike2024,
  author = {Koike, Yuhei and Takegawa, Hideki and Anetai, Yusuke and Nakamura, Satoaki and Yoshida, Ken and Yoshida, Asami and Yui, Midori and Hirota, Kazuki and Ueda, Kenichi and Tanigawa, Noboru},
  title = {Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2024},
  doi = {10.1007/s10278-024-01312-6}
}
Kostenlos starten →