A hybrid phenomenological finite element model of transcatheter aortic valve leaflet behaviour under non-circular annular deployment: in vitro validation and biomechanical insights
Biomechanics and Modeling in Mechanobiology · 2026
DOI: 10.1007/s10237-026-02112-3 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2026. Verfasst von David Agudo und 10 weiteren Autor:innen. Beteiligte Einrichtung: CINTECX, Department of Mechanical Engineering, Universidade de Vigo, Campus As Lagoas, Marcosende, 36310, Vigo, Galicia, Spain. david.agudo@uvigo.gal. Hauptthemen laut MEDLINE: Finite Element Analysis, Aortic Valve, Models, Cardiovascular, Transcatheter Aortic Valve Replacement. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia, Innovación y Universidades, Ministry of Science, Innovation and Universities, Universidade de Vigo.
Abstract (Originalsprache)
Transcatheter aortic valves (TAVs) typically operate on non-circular rings, but the impact of annular ellipticity on valve mechanics remains insufficiently quantified. In this study, we present a finite element (FE) framework of a 27 mm Allegra TAV that reproduces the complete model, including stent and pericardial skirt and leaflets. The leaflets were represented using a general shell formulation that decouples the in-plane and bending responses, leading to a hybrid shell–membrane finite element model. A linear elastic constitutive law was calibrated through inverse FE analysis based on cantilever bending experiments performed on bovine pericardium. The model was validated against in vitro pulse duplicator tests for circular and highly elliptical geometries, reproducing distinctive features such as full systolic opening and the asymmetric ‘pinwheel’ pattern during diastolic closure. Once validated, the model is used to investigate the impact of annular ellipticity across six annular aortic geometries. Each geometry was evaluated in two limiting orientations of the ellipse’s major axis (0 $$^\circ$$ ∘ and 90 $$^\circ$$ ∘ ) to analyse the model response in terms of valve coaptation. These results identify annular geometry and alignment as major factors in valve leaflet coaptation asymmetry and this asymmetry was found to correlate with increased stress concentration, which could compromise long-term valve function.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CINTECX, Department of Mechanical Engineering, Universidade de Vigo, Campus As Lagoas, Marcosende, 36310, Vigo, Galicia, Spain. david.agudo@uvigo.gal.
- Design and Numerical Simulation Research Group, Galicia Sur Health Research Institute, Vigo, Galicia, Spain. david.agudo@uvigo.gal.
- Nsilica Simulation Technologies, Nigrán, Galicia, Spain.
- CINTECX, Department of Mechanical Engineering, Universidade de Vigo, Campus As Lagoas, Marcosende, 36310, Vigo, Galicia, Spain.
- Design and Numerical Simulation Research Group, Galicia Sur Health Research Institute, Vigo, Galicia, Spain.
- Cardiovascular Research Group, Galicia Sur Health Research Institute, Vigo, Galicia, Spain.
Förderung
- Ministerio de Ciencia, Innovación y Universidades
- Ministry of Science, Innovation and Universities
- Universidade de Vigo
Zitieren
APA
Agudo, D., Comesaña, P., Suárez, S., Lopez-Garcia, I., Segade, A., Casarejos, E., Veiga, C., Busto, L., Jimenez-Díaz, V. A., Kütting, M., & Iñiguez, A. (2026). A hybrid phenomenological finite element model of transcatheter aortic valve leaflet behaviour under non-circular annular deployment: in vitro validation and biomechanical insights. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-026-02112-3
Vancouver
Agudo D, Comesaña P, Suárez S, Lopez-Garcia I, Segade A, Casarejos E, et al. A hybrid phenomenological finite element model of transcatheter aortic valve leaflet behaviour under non-circular annular deployment: in vitro validation and biomechanical insights. Biomechanics and Modeling in Mechanobiology. 2026. doi:10.1007/s10237-026-02112-3
BibTeX
@article{Agudo2026,
author = {Agudo, David and Comesaña, Pablo and Suárez, Sofía and Lopez-Garcia, Irea and Segade, Abraham and Casarejos, Enrique and Veiga, Cesar and Busto, Laura and Jimenez-Díaz, Victor Alfonso and Kütting, Maximilian and Iñiguez, Andres},
title = {A hybrid phenomenological finite element model of transcatheter aortic valve leaflet behaviour under non-circular annular deployment: in vitro validation and biomechanical insights},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2026},
doi = {10.1007/s10237-026-02112-3}
}
EUVIMED