EUVIMEDEUVIMED entdecken
BeobachtungsstudieMultizentrische StudieValidierungsstudie

Computed Tomography Derived Procedure Simulations for Redo Transcatheter Aortic Valve Replacement

Mark M P van den Dorpel iD, Ole de Backer iD, Mohamed Abdel-Wahab iD, Alessandro Beneduce, Nicolas Dumonteil, Daniel J Blackman, Yannick Willemen iD, James Dargan, Karl Poon, Joost Daemen iD, Lucas Uchoa de Assis iD, Jenna van Niekerk und 8 weitere

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70530 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Mark M P van den Dorpel und 19 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Institute, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands. Hauptthemen laut MEDLINE: Aortic Valve, Multidetector Computed Tomography, Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: FEops.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transcatheter aortic valve (TAV) failure may require redo transcatheter aortic valve replacement (redo‐TAVR). The multiple layers of metal after redo‐TAVR may jeopardize coronary artery patency and accessibility and result in prosthesis‐patient mismatch. Dedicated software may use multi‐slice computed tomography (MSCT) imaging to simulate TAV deployment relative to the prior TAV and the individual's anatomy and predict coronary accessibility and TAV expansion.

Aim

We aimed to validate redo‐TAVR simulations created in FEops HEARTguide.

Methods

This multicenter observational study included redo‐TAVR patients who had MSCT imaging available at baseline, after index‐TAVR and after redo‐TAVR. Patient‐specific redo‐TAVR simulations were created. Simulated valve‐to‐aorta distances (a proxy for coronary accessibility), neoskirt height, TAV expansion at multiple frame levels, and residual valve area after redo‐TAVR were compared to follow‐up MSCT.

Results

Among 25 patients, HEARTguide simulations of valve‐to‐coronary (VTC) distance (left VTC 6.0 ± 2.2 vs. 6.4 ± 2.3 mm, ICC = 0.856, p < 0.001; right VTC 5.8 ± 1.9 vs. 5.6 ± 1.9 mm, ICC = 0.740, p < 0.001) showed good agreement while valve‐to‐sinotubular‐junction (VTSTJ) distance showed moderate agreement with follow‐up MSCT (left VTSTJ 2.5 ± 1.8 vs. 3.3 ± 1.8 mm, ICC = 0.614, p = 0.004; right VTSTJ 2.8 ± 1.8 vs. 2.9 ± 1.2 mm, ICC = 0.613, p = 0.003). Redo‐TAVR frame expansion simulations (mean frame area 434.8 ± 141.6 vs. 401.6 ± 142.9 mm, ICC = 0.930, p < 0.001; 393.5 ± 63.2 vs. 383.1 ± 82.5 mm, ICC = 0.822, p < 0.001, respectively) and simulations of residual valve area after redo‐TAVR showed good agreement for self‐expanding and balloon‐expandable TAV (407.8 ± 67.8 vs. 389.6 ± 50.4 mm, ICC = 0.837, p < 0.001; 358.0 ± 66.1 vs. 336.1 ± 79.9 mm, ICC = 0.823, p < 0.001).

Conclusions

In this pilot study, MSCT‐derived simulations of redo‐TAVR provided accurate insights into coronary accessibility, TAV expansion, and residual valve area.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic ValveMultidetector Computed TomographyTranscatheter Aortic Valve ReplacementAortic Valve StenosisPatient-Specific ModelingModels, CardiovascularComputed Tomography AngiographyHumansPredictive Value of TestsAged, 80 and overFemaleHeart Valve ProsthesisTreatment OutcomeMaleReoperationAgedProsthesis DesignReproducibility of ResultsTime FactorsProsthesis FailureRadiographic Image Interpretation, Computer-Assisted

Stichwörter der Autor:innen

coronary accessibilityprosthesis‐patient mismatchredo‐TAVRsimulation

Autor:innen und Institutionen

  • Cardiovascular Institute, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands.
  • Department of Cardiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
  • Department of Cardiology, Heart Center Leipzig at University of Leipzig, Leipzig, Germany.
  • Department of Cardiology, Clinique Pasteur, Toulouse, France.
  • Department of Cardiology, Leeds Teaching Hospitals NHS Trust Leeds, Leeds, UK.
  • Department of Cardiology, St George's University Hospital NHS Foundation Trust, London, UK.

ORCID-Profile: Mark M P van den Dorpel, Ole de Backer, Mohamed Abdel-Wahab, Yannick Willemen, Joost Daemen, Lucas Uchoa de Assis, Nicolas M Van Mieghem

Förderung

  • FEops

Zitieren

APA

van den Dorpel, M. M. P., de Backer, O., Abdel-Wahab, M., Beneduce, A., Dumonteil, N., Blackman, D. J., Willemen, Y., Dargan, J., Poon, K., Daemen, J., de Assis, L. U., van Niekerk, J., Kardys, I., Tchetche, D., De Beule, M., Jan Nuis, R., Rocatello, G., Debusschere, N., Mortier, P., & Van Mieghem, N. M. (2026). Computed Tomography Derived Procedure Simulations for Redo Transcatheter Aortic Valve Replacement. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70530

Vancouver

van den Dorpel MMP, de Backer O, Abdel-Wahab M, Beneduce A, Dumonteil N, Blackman DJ, et al. Computed Tomography Derived Procedure Simulations for Redo Transcatheter Aortic Valve Replacement. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70530

BibTeX
@article{vandenDorpel2026,
  author = {van den Dorpel, Mark M P and de Backer, Ole and Abdel-Wahab, Mohamed and Beneduce, Alessandro and Dumonteil, Nicolas and Blackman, Daniel J and Willemen, Yannick and Dargan, James and Poon, Karl and Daemen, Joost and de Assis, Lucas Uchoa and van Niekerk, Jenna and Kardys, Isabella and Tchetche, Didier and De Beule, Matthieu and Jan Nuis, Rutger and Rocatello, Giorgia and Debusschere, Nic and Mortier, Peter and Van Mieghem, Nicolas M},
  title = {Computed Tomography Derived Procedure Simulations for Redo Transcatheter Aortic Valve Replacement},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70530}
}
Kostenlos starten →