A monolithic patient-specific 3D–0D model for In silico investigation of hemodynamics in patients with left ventricular assist devices
Biomechanics and Modeling in Mechanobiology · 2026-06 · 25 (3)
DOI: 10.1007/s10237-026-02063-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 03.06.2026. Verfasst von Mia Bonini und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA. mbonini@umich.edu. Hauptthemen laut MEDLINE: Heart-Assist Devices, Hemodynamics, Computer Simulation, Models, Cardiovascular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
We present a fully coupled, patient-specific 3D–0D computational framework for hearts supported with left ventricular assist devices (LVAD) that enables controlled in silico experimentation. The approach monolithically integrates three-dimensional CFD of the left ventricle (LV), left atrium (LA), aortic root, and LVAD cannulae with a closed-loop 0D lumped parameter network of the full circulation. Mitral and aortic valve dynamics are governed by transvalvular pressure and flow with patient-specific regurgitant orifice areas, and the LVAD is represented via a pressure–flow (H–Q) relation. This manuscript provides the complete mathematical formulation, coupling strategy, and parameterization required to build a reproducible pipeline from dynamic CT, 2D transthoracic echocardiography, and right heart catheterization. This methodology is demonstrated in a patient under long-term support of LVAD and concomitant mitral and aortic regurgitation. The personalized, fully coupled 3D–0D models reproduced available clinical targets with a mean error of 8.6%, enabling controlled in silico interrogation of valve repair strategies. In the patient-specific state, simulated mitral and aortic regurgitant volumes were 6.6 and 6.5 mL per cycle, yielding a forward cardiac output of 3.16 L/min despite an LVAD flow of 3.7 L/min. In silico isolated mitral valve (MV) repair, isolated aortic valve (AV) repair, and combined MV+AV repair increased forward output to 3.41, 3.33, and 3.55 L/min, respectively; however, aortic valve opening and increased aortic pressure pulsatility (up to 38.9 vs. 13.5 mmHg) were observed only when MV repair was involved. These left-sided improvements propagated through the cardiopulmonary circulation, reducing pulmonary pressures and right ventricular loading, with the largest benefit observed following combined repair. We show that the modeling platform presented provides a powerful means to study mechanical circulatory support, enabling patient-specific evaluation of surgical interventions in patients with LVAD and delivering quantitative insight into clinically important metrics—such as aortic pulsatility, RV afterload, and chamber-level flow patterns.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA. mbonini@umich.edu.
- Division 2.2 Process Simulation, Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin, Germany.
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, MI, USA.
- Department of Cardiac Surgery, Mayo Clinic, Rochester, MN, USA.
Zitieren
APA
Bonini, M., Hirschvogel, M., Ferguson, M., Pagani, F., Tang, P. C., & Nordsletten, D. (2026). A monolithic patient-specific 3D–0D model for In silico investigation of hemodynamics in patients with left ventricular assist devices. Biomechanics and Modeling in Mechanobiology, 25(3). https://doi.org/10.1007/s10237-026-02063-9
Vancouver
Bonini M, Hirschvogel M, Ferguson M, Pagani F, Tang PC, Nordsletten D. A monolithic patient-specific 3D–0D model for In silico investigation of hemodynamics in patients with left ventricular assist devices. Biomechanics and Modeling in Mechanobiology. 2026;25(3). doi:10.1007/s10237-026-02063-9
BibTeX
@article{Bonini2026,
author = {Bonini, Mia and Hirschvogel, Marc and Ferguson, Michael and Pagani, Francis and Tang, Paul C and Nordsletten, David},
title = {A monolithic patient-specific 3D–0D model for In silico investigation of hemodynamics in patients with left ventricular assist devices},
journal = {Biomechanics and Modeling in Mechanobiology},
year = {2026},
volume = {25},
number = {3},
doi = {10.1007/s10237-026-02063-9}
}
EUVIMED