Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, 2025. Verfasst von Jirong Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Minnesota, 7-114 NHH, 312 Church St SE, Minneapolis, MN, 55455, USA. Hauptthemen laut MEDLINE: Prosthesis Design, Heart Valve Prosthesis, Computer Simulation, Heart Valves. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A finite-element-based algorithm for the in silico construction of a novel tri-tube heart valve was developed to facilitate optimization of the leaflet geometry. An anisotropic hyperelastic model fitted to high-strain rate planar equibiaxial tension and compression data was used to approximate the nonlinear and anisotropic material behavior of biologically-engineered tubes and simulate valve closure under steady back pressure and steady forward flow. Four metrics were considered to evaluate valve performance in simulated closure: coaptation area, regurgitation area, pinwheel index, and prolapse area. Response surfaces revealed competing objectives between metrics for a valve of target 24 mm diameter in terms of two design parameters, tube diameter and leaflet height. A multi-objective genetic algorithm determined an intermediate tube diameter and leaflet height (16 mm and 11 mm, respectively) of the design space as optimal. Additionally, steady flow simulations were performed using two-way fluid–structure interaction with selected designs to examine washout behind leaflets with particle tracking. One design close to the optimal point for valve closure indicated washout for particles initially distributed behind leaflets. Though comprehensive valve design optimization requires flow analysis over multiple valve cycles to capture all effects associated with flow, this methodology based on diastolic state geometry optimization followed by steady washout analysis reduces the space of design variables for further optimization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis DesignHeart Valve ProsthesisComputer SimulationHeart ValvesFinite Element AnalysisAlgorithmsHumansModels, CardiovascularStress, Mechanical

Stichwörter der Autor:innen

CoaptationFinite element analysisFluid–structure interactionHeart valveOptimizationWashout

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of Minnesota, 7-114 NHH, 312 Church St SE, Minneapolis, MN, 55455, USA.
  • Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, USA.
  • Department of Biomedical Engineering, University of Minnesota, 7-114 NHH, 312 Church St SE, Minneapolis, MN, 55455, USA. tranquillo@umn.edu.
  • Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, MN, USA. tranquillo@umn.edu.

Förderung

  • NHLBI NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Li, J., Yu, Y., & Tranquillo, R. T. (2025). Computational construction and design optimization of a novel tri-tube heart valve. Biomechanics and Modeling in Mechanobiology. https://doi.org/10.1007/s10237-025-01956-5

Vancouver

Li J, Yu Y, Tranquillo RT. Computational construction and design optimization of a novel tri-tube heart valve. Biomechanics and Modeling in Mechanobiology. 2025. doi:10.1007/s10237-025-01956-5

BibTeX
@article{Li2025,
  author = {Li, Jirong and Yu, Yijiang and Tranquillo, Robert T},
  title = {Computational construction and design optimization of a novel tri-tube heart valve},
  journal = {Biomechanics and Modeling in Mechanobiology},
  year = {2025},
  doi = {10.1007/s10237-025-01956-5}
}
Kostenlos starten →