Carbon fiber–reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging
Neurosurgical Review · 2021-08 · 44 (4) · 2163-2170
DOI: 10.1007/s10143-020-01384-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurosurgical Review, online erschienen am 15.09.2020. Verfasst von Theresa Krätzig und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany. t.kraetzig@uke.de. Hauptthemen laut MEDLINE: Artifacts, Prostheses and Implants, Titanium. Die Arbeit wurde bisher 70-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Hamburg-Eppendorf (UKE).
Abstract (Originalsprache)
Artifacts in computed tomography (CT) and magnetic resonance imaging (MRI) due to titanium implants in spine surgery are known to cause difficulties in follow-up imaging, radiation planning, and precise dose delivery in patients with spinal tumors. Carbon fiber–reinforced polyetheretherketon (CFRP) implants aim to reduce these artifacts. Our aim was to analyze susceptibility artifacts of these implants using a standardized in vitro model. Titanium and CFRP screw-rod phantoms were embedded in 3% agarose gel. Phantoms were scanned with Siemens Somatom AS Open and 3.0-T Siemens Skyra scanners. Regions of interest (ROIs) were plotted and analyzed for CT and MRI at clinically relevant localizations. CT voxel–based imaging analysis showed a significant difference of artifact intensity and central overlay between titanium and CFRP phantoms. For the virtual regions of the spinal canal, titanium implants (ti) presented − 30.7 HU vs. 33.4 HU mean for CFRP ( p < 0.001), at the posterior margin of the vertebral body 68.9 HU (ti) vs. 59.8 HU (CFRP) ( p < 0.001) and at the anterior part of the vertebral body 201.2 HU (ti) vs. 70.4 HU (CFRP) ( p < 0.001), respectively. MRI data was only visually interpreted due to the low sample size and lack of an objective measuring system as Hounsfield units in CT. CT imaging of the phantom with typical implant configuration for thoracic stabilization could demonstrate a significant artifact reduction in CFRP implants compared with titanium implants for evaluation of index structures. Radiolucency with less artifacts provides a better interpretation of follow-up imaging, radiation planning, and more precise dose delivery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neurosurgery, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany. t.kraetzig@uke.de.
- Department of Neurosurgery, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany.
- Department of Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- Division of Spine Surgery, Department of Trauma and Orthopedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- Department of Radiation Oncology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Förderung
- Universitätsklinikum Hamburg-Eppendorf (UKE)
Zitieren
APA
Krätzig, T., Mende, K. C., Mohme, M., Kniep, H., Dreimann, M., Stangenberg, M., Westphal, M., Gauer, T., & Eicker, S. O. (2021). Carbon fiber–reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurgical Review, 44(4), 2163-2170. https://doi.org/10.1007/s10143-020-01384-2
Vancouver
Krätzig T, Mende KC, Mohme M, Kniep H, Dreimann M, Stangenberg M, et al. Carbon fiber–reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurgical Review. 2021;44(4):2163-2170. doi:10.1007/s10143-020-01384-2
BibTeX
@article{Krtzig2021,
author = {Krätzig, Theresa and Mende, Klaus C and Mohme, Malte and Kniep, Helge and Dreimann, Marc and Stangenberg, Martin and Westphal, Manfred and Gauer, Tobias and Eicker, Sven O},
title = {Carbon fiber–reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging},
journal = {Neurosurgical Review},
year = {2021},
volume = {44},
number = {4},
pages = {2163--2170},
doi = {10.1007/s10143-020-01384-2}
}
EUVIMED