EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hydrophilicity, wettability, and elemental analysis of zirconia implant ceramic after surface conditioning methods as a function of storage time

Dario Philipp Luterbach, Luiza Freitas Brum Souza, Tan Fırat Eyüboğlu, Mutlu Özcan

Clinical Oral Investigations · 2026

DOI: 10.1007/s00784-026-06854-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Investigations, 2026. Verfasst von Dario Philipp Luterbach und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Dental Medicine, Clinic of Masticatory Disorders and Dental Biomaterials, University of Zurich, Plattenstrasse 11, Zurich, CH-8032, Switze…. Hauptthemen laut MEDLINE: Zirconium, Ceramics, Dental Implants. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study evaluated how distinct surface-modification protocols and storage time affect the wettability, surface free energy (SFE), and elemental composition of zirconia. Materials and methods Zirconia specimens were subjected to six surface conditioning methods: Control (CT), alumina airborne-particle abrasion (110 μm) (AL), tribochemical silica coating (30 μm) (SI), chemical etching (ET), alumina+etching (AL-ET), and laser treatment (LS). Measurements were taken at baseline and after 1, 3, 6, and 12 months. Wettability was evaluated with water and diiodomethane contact angles to calculate work of adhesion (WoA) and surface free energy (SFE) via the Owens-Wendt-Rabel-Kaelble method. Elemental composition was assessed by energy-dispersive X-ray spectroscopy. Data analysis involved one-way ANOVA with Tukey`s post-hoc tests for treatment comparison and two-way ANOVA for storage-time effects.

Results

Surface conditioning significantly affected contact angle, WoA, and SFE (p < 0.05), compared to storage. SI had the lowest water contact angles, highest WoA, and highest SFE, with a strong polar component. AL improved wettability and SFE, but less than SI. While ET showed the least hydrophilic properties at baseline but improved over time, LS was intermediate and stable. CT became more hydrophilic after 6–12 months and SI remained best. EDS confirmed these trends, with persistent silica, low aluminum after alumina treatment, and treatment-dependent elemental changes. The CT and LS spectra resembled those of the substrate.

Conclusions

Both the surface-modification strategy and storage time affected zirconia wettability, with surface modification playing a greater role. While tribochemical silica coating created a durable, hydrophilic surface, Al 2 O 3 was less effective. Etching needed time to remove residues and laser treatment offered intermediate stability. Clinical relevance Tribochemical silica coating provided the best zirconia implant surface by maintaining a durable, hydrophilic, high surface-free energy state tha t may promote early protein interaction and predictable osseointegration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZirconiumCeramicsDental ImplantsWettabilitySurface PropertiesTime FactorsMaterials TestingHydrophobic and Hydrophilic InteractionsSpectrometry, X-Ray Emission

Stichwörter der Autor:innen

Air-abrasionDental materialsEtchingLaserOral implantsSurface conditioningSurface free energyUltrasonic cleaningWettabilityZirconia

Substanzen

Zirconiumzirconium oxideDental Implants

Autor:innen und Institutionen

  • Center for Dental Medicine, Clinic of Masticatory Disorders and Dental Biomaterials, University of Zurich, Plattenstrasse 11, Zurich, CH-8032, Switzerland.
  • Faculty of Dentistry, Department of Endodontics, Istanbul Medipol University, Istanbul, Türkiye, Turkey.
  • Center for Dental Medicine, Clinic of Masticatory Disorders and Dental Biomaterials, University of Zurich, Plattenstrasse 11, Zurich, CH-8032, Switzerland. mutluozcan@hotmail.com.

Zitieren

APA

Luterbach, D. P., Souza, L. F. B., Eyüboğlu, T. F., & Özcan, M. (2026). Hydrophilicity, wettability, and elemental analysis of zirconia implant ceramic after surface conditioning methods as a function of storage time. Clinical Oral Investigations. https://doi.org/10.1007/s00784-026-06854-3

Vancouver

Luterbach DP, Souza LFB, Eyüboğlu TF, Özcan M. Hydrophilicity, wettability, and elemental analysis of zirconia implant ceramic after surface conditioning methods as a function of storage time. Clinical Oral Investigations. 2026. doi:10.1007/s00784-026-06854-3

BibTeX
@article{Luterbach2026,
  author = {Luterbach, Dario Philipp and Souza, Luiza Freitas Brum and Eyüboğlu, Tan Fırat and Özcan, Mutlu},
  title = {Hydrophilicity, wettability, and elemental analysis of zirconia implant ceramic after surface conditioning methods as a function of storage time},
  journal = {Clinical Oral Investigations},
  year = {2026},
  doi = {10.1007/s00784-026-06854-3}
}
Kostenlos starten →