EUVIMEDEUVIMED entdecken
Crossref

Comparison of five rotary systems regarding design, metallurgy, mechanical performance, and canal preparation—a multimethod research

Jorge N R Martins, Emmanuel João Nogueira Leal Silva, Duarte Marques, Felipe Gonçalves Belladonna, Marco Simões-Carvalho, Rui Pereira da Costa, António Ginjeira, Francisco Manuel Braz Fernandes, Marco Aurélio Versiani

Clinical Oral Investigations · 2022-03 · 26 (3) · 3299-3310

DOI: 10.1007/s00784-021-04311-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Investigations, 2022-03. Verfasst von Jorge N R Martins und 8 weiteren Autor:innen. Beteiligte Einrichtung: Faculdade de Medicina Dentária, Universidade de Lisboa, Cidade Universitária, 1649-003, Lisbon, Portugal. jnr_martins@yahoo.com.br. Hauptthemen laut MEDLINE: Dental Alloys, Root Canal Preparation. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: fundação para a ciência e a tecnologia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To compare the design, metallurgy, mechanical performance, and canal preparation of 5 rotary systems. MATERIAL AND METHODS: A total of 735 25-mm NiTi instruments (sizes 0.17[0.18]/.02v, 0.20/.04v, 0.20/.07v, 0.25/.08v, 0.30/.09v) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-File systems were compared regarding overall geometry and surface finishing (stereomicroscopy and scanning electron microscopy), nickel and titanium ratio (energy-dispersive spectroscopy), phase transformation temperatures (differential scanning calorimetry), mechanical performance (torsional and bending tests), and unprepared canal surface (micro-CT). One-way ANOVA and Mood's median tests were used for statistical comparisons with a significance level set at 5%. RESULTS: Stereomicroscopic analysis showed more spirals and high helical angles in the Premium Taper Gold system. All sets of instruments had symmetrical spirals, no radial lands, no major defects, and an almost equiatomic ratio between nickel and titanium elements, while differences were observed in their tips' geometry and surface finishing. At room temperature (20 °C), DSC test revealed martensitic characteristics for ProTaper Gold and Go-Taper Flex, and mixed austenite plus R-phase for the Premium Taper Gold, while ProTaper Universal and U-Files had full austenitic characteristics. Overall, larger instruments had higher torque resistance and bending load values than smaller ones, while a lack of consistency and mixed values were observed in the angle of rotation. The 0.25/.08v and 0.30/.09v instruments of ProTaper Universal and U-File had the highest maximum torques, the lowest angles of rotation, and the highest bending loads than other tested systems (P .05). CONCLUSIONS: Although differences observed in the overall geometry and phase transformation temperatures have influenced the results of mechanical tests, unprepared canal surface areas were equivalent among systems. CLINICAL RELEVANCE: Root canal preparation systems with similar geometries might present different mechanical behaviors but equivalent shaping ability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental AlloysRoot Canal PreparationEquipment DesignMaterials TestingMetallurgyStress, MechanicalTitanium

Stichwörter der Autor:innen

Bending loadDifferential scanning calorimetryEndodonticsMicro-CTNickel-titanium alloyRoot canal therapyScanning electron microscopyTorsional strength

Substanzen

Dental AlloysTitanium

Autor:innen und Institutionen

  • Faculdade de Medicina Dentária, Universidade de Lisboa, Cidade Universitária, 1649-003, Lisbon, Portugal. jnr_martins@yahoo.com.br.
  • Grupo de Investigação Em Bioquimica E Biologia Oral, Faculdade de Medicina Dentária, Unidade de Investigação Em Ciências Orais E Biomédicas (UICOB), Universidade de Lisboa, Lisbon, Portugal. jnr_martins@yahoo.com.br.
  • Centro de Estudo de Medicina Dentária Baseada Na Evidência (CEMDBE) - Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal. jnr_martins@yahoo.com.br.
  • Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Rio de Janeiro, Brazil.
  • Department of Endodontics, Fluminense Federal University, Niteroi, Rio de Janeiro, Brazil.
  • Faculdade de Medicina Dentária, Universidade de Lisboa, Cidade Universitária, 1649-003, Lisbon, Portugal.

Förderung

  • fundação para a ciência e a tecnologia

Zitieren

APA

Martins, J. N. R., Silva, E. J. N. L., Marques, D., Belladonna, F. G., Simões-Carvalho, M., da Costa, R. P., Ginjeira, A., Braz Fernandes, F. M., & Versiani, M. A. (2022). Comparison of five rotary systems regarding design, metallurgy, mechanical performance, and canal preparation—a multimethod research. Clinical Oral Investigations. https://doi.org/10.1007/s00784-021-04311-x

Vancouver

Martins JNR, Silva EJNL, Marques D, Belladonna FG, Simões-Carvalho M, da Costa RP, et al. Comparison of five rotary systems regarding design, metallurgy, mechanical performance, and canal preparation—a multimethod research. Clinical Oral Investigations. 2022. doi:10.1007/s00784-021-04311-x

BibTeX
@article{Martins2022,
  author = {Martins, Jorge N R and Silva, Emmanuel João Nogueira Leal and Marques, Duarte and Belladonna, Felipe Gonçalves and Simões-Carvalho, Marco and da Costa, Rui Pereira and Ginjeira, António and Braz Fernandes, Francisco Manuel and Versiani, Marco Aurélio},
  title = {Comparison of five rotary systems regarding design, metallurgy, mechanical performance, and canal preparation—a multimethod research},
  journal = {Clinical Oral Investigations},
  year = {2022},
  doi = {10.1007/s00784-021-04311-x}
}
Kostenlos starten →