Crestal bone loss and implant failure of prefabricated versus customized abutments: a 10-year retrospective radiological study

Georgios E Romanos, Seymur Gurbanov, Pablo Hess, Georg-Hubertus Nentwig, Frank Schwarz, Robert Sader

Clinical Oral Investigations · 2022-03 · 26 (3) · 2879-2886

DOI: 10.1007/s00784-021-04269-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 12.11.2021. Verfasst von Georgios E Romanos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Surgery and Implant Dentistry, School of Dentistry, Johann Wolfgang Goethe University, Frankfurt, Germany. georgios.romanos@stonyb…. Hauptthemen laut MEDLINE: Alveolar Bone Loss, Dental Implants. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: There is no information today about the impact of abutment type on the crestal bone stability. This retrospective study was aimed to evaluate the crestal bone levels (CBL) and failures of implants with prefabricated and customized abutments after the long term. MATERIALS AND METHODS: The mesial and distal CBL around dental implants with prefabricated and custom abutments were recorded. Measures were completed at 5- and 10-year endpoints. RESULTS: Sixty-three patients with 249 implants were included. One hundred twenty-seven implants (51%) were restored with prefabricated and 122 implants (49%) with customized abutments. All the patients received fixed restorations. The results showed that the CBL was higher in patients with custom abutments than the CBL of patients with prefabricated abutments. The mean bone loss around implants with prefabricated abutments was 0.29 mm mesial/0.45 mm distal after 10 years. Meanwhile, the mean bone loss at implants with custom abutments was 1.19 mm mesial/1.27 mm distal (p < 0.05) after 10 years. None of the implants with prefabricated abutments failed up to 10-year follow-up, whereas 4.1% of implants with customized abutments failed. CONCLUSION: Implants with prefabricated abutments present less crestal bone loss compared to customized abutments. CLINICAL RELEVANCE: The selection of abutment type is associated with the crestal bone stability or marginal bone loss.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Alveolar Bone LossDental ImplantsDental AbutmentsDental Implantation, EndosseousDental Prosthesis, Implant-SupportedFollow-Up StudiesHumansRetrospective Studies

Stichwörter der Autor:innen

Crestal bone lossCustom abutmentsDental implantsPrefabricated abutments

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Oral Surgery and Implant Dentistry, School of Dentistry, Johann Wolfgang Goethe University, Frankfurt, Germany. georgios.romanos@stonybrook.edu.
  • Department of Periodontology, School of Dental Medicine, Stony Brook University, Stony Brook, NY, USA. georgios.romanos@stonybrook.edu.
  • Department of Oral Surgery and Implant Dentistry, School of Dentistry, Johann Wolfgang Goethe University, Frankfurt, Germany.
  • Department of Oral and Maxillofacial Surgery, School of Medicine, Johann Wolfgang Goethe University, Frankfurt, Germany.

Zitieren

APA

Romanos, G. E., Gurbanov, S., Hess, P., Nentwig, G. H., Schwarz, F., & Sader, R. (2022). Crestal bone loss and implant failure of prefabricated versus customized abutments: a 10-year retrospective radiological study. Clinical Oral Investigations, 26(3), 2879-2886. https://doi.org/10.1007/s00784-021-04269-w

Vancouver

Romanos GE, Gurbanov S, Hess P, Nentwig GH, Schwarz F, Sader R. Crestal bone loss and implant failure of prefabricated versus customized abutments: a 10-year retrospective radiological study. Clinical Oral Investigations. 2022;26(3):2879-2886. doi:10.1007/s00784-021-04269-w

BibTeX
@article{Romanos2022,
  author = {Romanos, Georgios E and Gurbanov, Seymur and Hess, Pablo and Nentwig, Georg-Hubertus and Schwarz, Frank and Sader, Robert},
  title = {Crestal bone loss and implant failure of prefabricated versus customized abutments: a 10-year retrospective radiological study},
  journal = {Clinical Oral Investigations},
  year = {2022},
  volume = {26},
  number = {3},
  pages = {2879--2886},
  doi = {10.1007/s00784-021-04269-w}
}
Kostenlos starten →