Long‐term performance of implants with moderately rough anodized surface supporting single‐tooth restorations: A retrospective analysis with an up to 15‐year follow‐up
Clinical Oral Implants Research · 2023
DOI: 10.1111/clr.14048 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2023. Verfasst von Jan Kowar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Brånemark Clinic Gothenburg, Public Dental Health Care Region Västra Götaland, Gothenburg, Sweden. Hauptthemen laut MEDLINE: Dental Implants, Alveolar Bone Loss. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Nobel Biocare Services AG.
Abstract (Originalsprache)
Objectives
This retrospective study aimed to evaluate long‐term clinical and radiologic performance of anodized surface implants supporting single implant restorations. Materials and Methods Patients who received at least one anodized surface implant for a single‐tooth restoration between 2003 and 2004 in the Brånemark clinic (Göteborg, Sweden) were included in the study. The assessed outcomes included implant survival, biological and technical complications, as well as marginal bone levels (MBL) based on radiographs. Baseline data on patient demographics, implant placement, and surgery details were also collected. The cumulative survival rate (CSR) was calculated using the Kaplan–Meier survival analysis.
Results
The study included 97 patients with 129 implants. Mean patient age at the time of implant placement was 31.7 ± 16.4 years. All implants were placed in a two‐stage approach with delayed loading. The last follow‐up visit was on average 13.4 ± 4.8 years after implant insertion. Three implants failed, yielding the implant‐level 15‐year CSR of 97.4%. Majority of the implants had no biological (70.5%) nor technical (81.4%) complications. The mean MBL was −1.0 ± 0.7 mm ( n = 101) at prosthetic placement and −1.8 ± 1.0 mm ( n = 80) at the last follow‐up, while the mean marginal bone loss (MBL) from prosthetic placement to last follow‐up was 0.6 ± 1.1 mm ( n = 65).
Conclusions
Moderately rough anodized implants have shown favorable long‐term outcomessingle‐tooth indication, with high survival and a low rate of technical complications. Furthermore, long‐term studies are needed to present longitudinal data on peri‐implantitis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Brånemark Clinic Gothenburg, Public Dental Health Care Region Västra Götaland, Gothenburg, Sweden.
- Department of Prosthodontics/Dental Materials Science, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
- Department of Oral and Maxillofacial radiology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
ORCID-Profile: Jan Kowar
Förderung
- Nobel Biocare Services AG
Zitieren
APA
Kowar, J., Lund, H., & Stenport, V. F. (2023). Long‐term performance of implants with moderately rough anodized surface supporting single‐tooth restorations: A retrospective analysis with an up to 15‐year follow‐up. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14048
Vancouver
Kowar J, Lund H, Stenport VF. Long‐term performance of implants with moderately rough anodized surface supporting single‐tooth restorations: A retrospective analysis with an up to 15‐year follow‐up. Clinical Oral Implants Research. 2023. doi:10.1111/clr.14048
BibTeX
@article{Kowar2023,
author = {Kowar, Jan and Lund, Henrik and Stenport, Victoria Franke},
title = {Long‐term performance of implants with moderately rough anodized surface supporting single‐tooth restorations: A retrospective analysis with an up to 15‐year follow‐up},
journal = {Clinical Oral Implants Research},
year = {2023},
doi = {10.1111/clr.14048}
}
EUVIMED