Robustness and Sensitivity of Gd(III)–Gd(III) Double Electron–Electron Resonance (DEER) Measurements: Comparative Study of High-Frequency EPR Spectrometer Designs and Spin Label Variants
Applied Magnetic Resonance · 2025-05 · 56 (5) · 591-611
DOI: 10.1007/s00723-024-01741-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Magnetic Resonance, online erschienen am 03.01.2025. Verfasst von Elena M Mocanu und 9 weiteren Autor:innen. Beteiligte Einrichtung: SUPA School of Physics and Astronomy and BSRC, University of St Andrews, North Haugh, St Andrews, KY16 9SS UK. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bluston Making Connections, Wellcome Trust, Biotechnology and Biological Sciences Research Council.
Abstract (Originalsprache)
In this paper, we explore the robustness and sensitivity of Gd(III)-Gd(III) double electron–electron resonance (DEER) distance measurements in proteins for different spectrometer designs and three spin labels. To do this a protein was labeled at the same two positions with Gd(III) spin labels and measurements were performed on two home-built high-frequency (W-band, ~ 95 GHz) EPR spectrometers with different design approaches, and a commercial 150 W Q-band (34 GHz) spectrometer. The first W-band measurement approach uses a conventional, narrow band single mode cavity, while the second uses a broadband non-resonant induction mode sample holder. Both systems incorporate advanced arbitrary waveform generators (AWGs) that give flexibility over excitation bandwidth. We use three DOTA-like Gd(III) spin labels, Gd.C12, Gd.DO3A and Gd.L 1 , conjugated to the calmodulin protein. We compare measurements taken by including or excluding the Gd(III) central transition excitation. The advantages and disadvantages of the EPR spectrometers for the measurement of Gd(III)–Gd(III) DEER are discussed in terms of the robustness of the resulting distance distribution width, absolute and concentration sensitivity, sample handling, ease of use, and flexibility of measurement.
Autor:innen und Institutionen
- SUPA School of Physics and Astronomy and BSRC, University of St Andrews, North Haugh, St Andrews, KY16 9SS UK.
- Department of Chemical and Biological Physics, Weizmann Institute of Science, 7610001 Rehovot, Israel.
- Department of Chemistry, Loughborough University, Epinal Way, Loughborough, LE11 3TU UK.
- State Key Laboratory of Elemento-Organic Chemistry, Tianjin Key Laboratory of Biosensing and Molecular Recognition, College of Chemistry, Nankai University, Tianjin, China.
ORCID-Profile: Elena M Mocanu, Yasmin Ben-Ishay, Lydia Topping, S Ronan Fisher, Robert I Hunter, Xun-Cheng Su, Stephen J Butler, Graham M Smith, Daniella Goldfarb, Janet E Lovett
Förderung
- Bluston Making Connections
- Wellcome Trust
- Biotechnology and Biological Sciences Research Council
- Royal Society
- Carnegie Trust
- Engineering and Physical Sciences Research Council
Zitieren
APA
Mocanu, E. M., Ben-Ishay, Y., Topping, L., Fisher, S. R., Hunter, R. I., Su, X. C., Butler, S. J., Smith, G. M., Goldfarb, D., & Lovett, J. E. (2025). Robustness and Sensitivity of Gd(III)–Gd(III) Double Electron–Electron Resonance (DEER) Measurements: Comparative Study of High-Frequency EPR Spectrometer Designs and Spin Label Variants. Applied Magnetic Resonance, 56(5), 591-611. https://doi.org/10.1007/s00723-024-01741-0
Vancouver
Mocanu EM, Ben-Ishay Y, Topping L, Fisher SR, Hunter RI, Su XC, et al. Robustness and Sensitivity of Gd(III)–Gd(III) Double Electron–Electron Resonance (DEER) Measurements: Comparative Study of High-Frequency EPR Spectrometer Designs and Spin Label Variants. Applied Magnetic Resonance. 2025;56(5):591-611. doi:10.1007/s00723-024-01741-0
BibTeX
@article{Mocanu2025,
author = {Mocanu, Elena M and Ben-Ishay, Yasmin and Topping, Lydia and Fisher, S Ronan and Hunter, Robert I and Su, Xun-Cheng and Butler, Stephen J and Smith, Graham M and Goldfarb, Daniella and Lovett, Janet E},
title = {Robustness and Sensitivity of Gd(III)–Gd(III) Double Electron–Electron Resonance (DEER) Measurements: Comparative Study of High-Frequency EPR Spectrometer Designs and Spin Label Variants},
journal = {Applied Magnetic Resonance},
year = {2025},
volume = {56},
number = {5},
pages = {591--611},
doi = {10.1007/s00723-024-01741-0}
}
EUVIMED