A high‐sensitivity stopped‐flow EPR system to monitor millisecond conformational kinetics in spin‐labeled proteins
Protein Science · 2025-08 · 34 (8)
DOI: 10.1002/pro.70214 ↗Kurz gefasst
Fachartikel in der Zeitschrift Protein Science, online erschienen am 16.07.2025. Verfasst von Alexander M Garces und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin, USA. Hauptthemen laut MEDLINE: Spin Labels, Muramidase, Receptors, Adrenergic, beta-2. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, National Institute of General Medical Sciences.
Abstract (Originalsprache)
Electron paramagnetic resonance (EPR) spectroscopy is a powerful tool for studying biological systems, with applications in drug discovery, protein dynamics, membrane biology, and enzyme mechanisms. However, sample volume requirements and sensitivity limitations have historically constrained time‐resolved measurements of protein dynamics using stopped‐flow (SF) EPR spectroscopy. To address these challenges, we developed a high‐sensitivity SF EPR system featuring a custom dielectric resonator, an optimized low‐volume sample tube geometry design, and the SF mixer assembly integrated into the resonator housing. This system significantly reduces sample requirements for the investigation of protein conformational dynamics on the millisecond timescale. We demonstrate its capabilities through two applications: the analysis of T4 lysozyme unfolding kinetics, which revealed site‐specific variations in the folding pathway, and the measurement of ligand‐induced conformational changes in the β2 adrenergic receptor, a challenging membrane‐protein system. This advancement broadens the applicability of SF EPR to complex, biomedically relevant proteins, facilitating studies of protein–protein and protein–ligand interactions in diverse biological processes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
- Department of Physics and Chemistry, Milwaukee School of Engineering, Milwaukee, Wisconsin, USA.
ORCID-Profile: Alexander M Garces, Candice S Klug, Jason W Sidabras, Michael T Lerch
Förderung
- NIGMS NIH HHS
- National Institute of General Medical Sciences
Zitieren
APA
Garces, A. M., Mett, R. R., Klug, C. S., Sidabras, J. W., & Lerch, M. T. (2025). A high‐sensitivity stopped‐flow EPR system to monitor millisecond conformational kinetics in spin‐labeled proteins. Protein Science, 34(8). https://doi.org/10.1002/pro.70214
Vancouver
Garces AM, Mett RR, Klug CS, Sidabras JW, Lerch MT. A high‐sensitivity stopped‐flow EPR system to monitor millisecond conformational kinetics in spin‐labeled proteins. Protein Science. 2025;34(8). doi:10.1002/pro.70214
BibTeX
@article{Garces2025,
author = {Garces, Alexander M and Mett, Richard R and Klug, Candice S and Sidabras, Jason W and Lerch, Michael T},
title = {A high‐sensitivity stopped‐flow EPR system to monitor millisecond conformational kinetics in spin‐labeled proteins},
journal = {Protein Science},
year = {2025},
volume = {34},
number = {8},
doi = {10.1002/pro.70214}
}
EUVIMED