Integration of intraoperative ultrasound and depth-electrode electrocorticography for resection guidance in epilepsy surgery: technical workflow and feasibility
Acta Neurochirurgica · 2026
DOI: 10.1007/s00701-026-06792-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Neurochirurgica, 2026. Verfasst von Luca Zanuttini und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, IRCCS Istituto Delle Scienze Neurologiche Di Bologna (ISNB), Bellaria Hospital, Via Altura 3, 40139, Bologna, Italy. luca…. Hauptthemen laut MEDLINE: Electrocorticography, Drug Resistant Epilepsy, Intraoperative Neurophysiological Monitoring, Neurosurgical Procedures. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alma Mater Studiorum - Università di Bologna.
Abstract (Originalsprache)
Background
Complete resection of the epileptogenic zone (EZ) is the strongest predictor of seizure freedom in drug-resistant epilepsy (DRE). However, even in MRI-positive cases with anatomo-electro-clinical concordance, the EZ may not be clearly delineated, complicating intraoperative decision-making. Intraoperative ultrasound (ioUS) provides real-time anatomical feedback, while depth-electrode intraoperative electrocorticography (iECoG) enables electrophysiological delineation of epileptogenic tissue beyond the cortical surface, sampling deep regions not accessible to subdural electrodes. Their integration may improve intraoperative precision in defining resection limits and optimizing resective surgery.
Methods
This study describes the workflow and feasibility of combining ioUS and depth-electrode iECoG for intraoperative guidance in MRI-positive focal DRE with an ill-defined EZ. In all cases, concordant anatomo-electro-clinical data identified a single EZ for which SEEG was not required, yet the suspected EZ remained poorly delineated. ioUS was used for real-time lesion visualization, verification of electrode trajectories, and guidance of resection depth and extent. Pre- and post-resective depth-electrode iECoG and ioUS were used in combination to delineate the resection margins, by identifying interictal epileptiform discharges (IEDs) and confirming lesion boundaries and resection completeness.
Results
Six patients underwent resective surgery using the combined ioUS–iECoG workflow. The technique was feasible and safe in all cases, with no intraoperative or postoperative complications (37 depth-electrode insertions). iECoG revealed IEDs in four patients (66%), prompting resection extension in two. MRI confirmed complete resection in all cases. At last follow-up (6–40 months), 5/6 patients were seizure-free (Engel I). Histopathology revealed FCD IIb in three cases, a gliotic lesion related to an encephalocele in one, a gliotic scar post–arachnoid cyst marsupialization in another, and a tuberous sclerosis–related lesion in a case of tuberous-sclerosis-complex.
Conclusion
The integration of ioUS and depth-electrode iECoG offers real-time anatomical and electrophysiological data, refining EZ delineation and resection assessment in complex MRI-positive epilepsy cases where SEEG is not clinically indicated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, IRCCS Istituto Delle Scienze Neurologiche Di Bologna (ISNB), Bellaria Hospital, Via Altura 3, 40139, Bologna, Italy. luca.zanuttini@studio.unibo.it.
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy. luca.zanuttini@studio.unibo.it.
- Epilepsy Program, Full Member of European Reference Network EpiCARE, IRCCS Istituto Delle Scienze Neurologiche Di Bologna, Bologna, Italy.
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy.
- Department of Neurosurgery, IRCCS Istituto Delle Scienze Neurologiche Di Bologna (ISNB), Bellaria Hospital, Via Altura 3, 40139, Bologna, Italy.
Förderung
- Alma Mater Studiorum - Università di Bologna
Zitieren
APA
Zanuttini, L., Pasini, E., Ferri, L., Di Vito, L., Scarabello, A., Bisulli, F., & Martinoni, M. (2026). Integration of intraoperative ultrasound and depth-electrode electrocorticography for resection guidance in epilepsy surgery: technical workflow and feasibility. Acta Neurochirurgica. https://doi.org/10.1007/s00701-026-06792-9
Vancouver
Zanuttini L, Pasini E, Ferri L, Di Vito L, Scarabello A, Bisulli F, et al. Integration of intraoperative ultrasound and depth-electrode electrocorticography for resection guidance in epilepsy surgery: technical workflow and feasibility. Acta Neurochirurgica. 2026. doi:10.1007/s00701-026-06792-9
BibTeX
@article{Zanuttini2026,
author = {Zanuttini, Luca and Pasini, Elena and Ferri, Lorenzo and Di Vito, Lidia and Scarabello, Anna and Bisulli, Francesca and Martinoni, Matteo},
title = {Integration of intraoperative ultrasound and depth-electrode electrocorticography for resection guidance in epilepsy surgery: technical workflow and feasibility},
journal = {Acta Neurochirurgica},
year = {2026},
doi = {10.1007/s00701-026-06792-9}
}
EUVIMED