Intraoperative ECoG in bottom‐of‐the‐sulcus syndrome using a novel flexible strip electrode
Epileptic Disorders · 2024
DOI: 10.1002/epd2.20211 ↗Kurz gefasst
Fallbericht in der Zeitschrift Epileptic Disorders, 2024. Verfasst von Niccolò Biagioli und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Metabolic Sciences and Neurosciences, University of Modena and Reggio Emilia, Modena, Italy. Hauptthemen laut MEDLINE: Drug Resistant Epilepsy, Electrocorticography. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
The recording of epileptiform discharges from bottom‐of‐sulcus focal cortical dysplasia (BOSD) is often difficult during intraoperative electrocorticography (ECoG) due to the deep localization. We describe the use in this scenario of a new‐generation electrode strip with high flexibility, easily adapted to cortical gyri and sulci. A right‐handed 20‐year‐old male with drug‐resistant focal epilepsy due to BOSD of the inferior frontal gyrus and daily focal aware seizures was evaluated for epilepsy surgery. Based on electroclinical and neuroimaging results, a focal cortectomy guided by ECoG was proposed. ECoG recordings were performed with new‐generation cortical strips (Wise Cortical Strip; WCS®) and standard cortical strips. ECoG, performed on the convexity of the frontal cortical surface, recorded only sporadic spikes with both types of strips. Then, after microsurgical trans‐sulcal dissection, WCS was molded along the sulcal surface of the suspected BOSD based on 3D‐imaging reconstruction, showing continuous/subcontinuous 3–4‐Hz rhythmic spike activity from the deepest electrode. Registration after resection of the BOSD did not show any epileptiform activity. Pathology showed dysmorphic neurons and gliosis. No surgical complications occurred. The patient is seizure‐free after 12 months. This single case experience shows that highly flexible electrode strips with adaptability to cortical gyrations can identify IEDs originating from deep location and could therefore be useful in cases of bottom of the sulcus dysplasia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Metabolic Sciences and Neurosciences, University of Modena and Reggio Emilia, Modena, Italy.
- Neurology Unit, Head and Neck Neuroscience Department, AOU, Modena, Italy.
- Clinical Neurophysiology Unit, Head and Neck Neuroscience Department, AOU, Modena, Italy.
- Neurosurgery Unit, Head and Neck Neuroscience Department, AOU, Modena, Italy.
ORCID-Profile: Niccolò Biagioli, Anna Elisabetta Vaudano, Matteo Pugnaghi, Stefano Meletti
Zitieren
APA
Biagioli, N., Morandi, S., Vaudano, A. E., Pugnaghi, M., Moriconi, E., Pavesi, G., Tramontano, V., & Meletti, S. (2024). Intraoperative ECoG in bottom‐of‐the‐sulcus syndrome using a novel flexible strip electrode. Epileptic Disorders. https://doi.org/10.1002/epd2.20211
Vancouver
Biagioli N, Morandi S, Vaudano AE, Pugnaghi M, Moriconi E, Pavesi G, et al. Intraoperative ECoG in bottom‐of‐the‐sulcus syndrome using a novel flexible strip electrode. Epileptic Disorders. 2024. doi:10.1002/epd2.20211
BibTeX
@article{Biagioli2024,
author = {Biagioli, Niccolò and Morandi, Sofia and Vaudano, Anna Elisabetta and Pugnaghi, Matteo and Moriconi, Elisa and Pavesi, Giacomo and Tramontano, Vincenzo and Meletti, Stefano},
title = {Intraoperative ECoG in bottom‐of‐the‐sulcus syndrome using a novel flexible strip electrode},
journal = {Epileptic Disorders},
year = {2024},
doi = {10.1002/epd2.20211}
}
EUVIMED