EUVIMEDEUVIMED entdecken
Crossref

A dual-response ratiometric fluorescent probe based on Tb3+/Eu3+-functionalized MOF-membrane on silica microspheres: highly selective detection of cefixime and tetracyclines via a built-in self-calibration strategy

Junlong Li, Zerong Long, Xiaofei Li, Jianling Wang, Tianli Fan, Kai Wang

Microchimica Acta · 2026

DOI: 10.1007/s00604-026-08260-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Junlong Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Chinese Pharmacy, Xinjiang Medical University, Urumqi, Xinjiang, PR China. Hauptthemen laut MEDLINE: Cefixime, Tetracyclines, Fluorescent Dyes, Metal-Organic Frameworks. Die Arbeit nennt 55 Literaturangaben. Gefördert von: Xinjiang Uygur Autonomous Region Graduate Student Research and Innovation Program Grants, Natural Science Foundation of Xinjiang Uygur Autonomous Region.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Adual-response ratiometric fluorescent probe based on Tb3+- and Eu3+-codoped metal-organic framework (MOF) membrane on silica microspheres (denoted as SiO2@(Tb: Eu)-BPDC) was fabricated. Benefiting from the orientation growth of Tb3+/Eu3+-MOF around the silica microspheres to achieve a uniform thin film with a thickness of 5-8 nm, the dual-channel transient ratiometric fluorescences are obtained. The responses are exhibited as an "on-off" mode for CFM (Ex = 322 nm, F615/F544) via a photoinduced electron transfer (PET) process, and an "off-on" response for tetracycline (TC) or cefixime (CFM) (Ex = 406 nm, F617/F592) through a target-sensitized "antenna effect". The established linear correlations demonstrated high sensitivity for CFM with a limit of detection (LOD) of 4 ng mL- 1 and 24 ng mL- 1 for TC. Both CFM and TC showed satisfactory spiked recoveries of 91‒114% in herbal tea beverage and milk samples, with relative standard deviations (RSDs) below 3.5%. Subsequently, an intelligent detection platform integrating a smartphone and the probe is developed, enabling qualitative and quantitative analysis for the target antibiotics by color gradient recognition. The research presents a sensitive and accurate sensing platform for in situ and visual monitoring of antibiotics by using the dual-mode sensing to eliminate cross-interference among different analytes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CefiximeTetracyclinesFluorescent DyesMetal-Organic FrameworksAnti-Bacterial AgentsTetracyclineSilicon DioxideEuropiumTerbiumMicrospheresLimit of DetectionMilkSpectrometry, FluorescenceFluorescent Chemosensor CompoundsAnimalsCalibration

Stichwörter der Autor:innen

CFMCefiximeDual-mode sensingRatiometric fluorescenceTCTb3+/Eu3+-MOF membraneTetracycline

Substanzen

CefiximeSilicon DioxideEuropiumTerbiumTetracyclinesFluorescent DyesMetal-Organic FrameworksAnti-Bacterial AgentsFluorescent Chemosensor CompoundsTetracycline

Autor:innen und Institutionen

  • School of Chinese Pharmacy, Xinjiang Medical University, Urumqi, Xinjiang, PR China.
  • Xinjiang Uygur Autonomous Region Quality Basic Development Research Institute, Urumqi, Xinjiang, PR China. long8326rong@163.com.
  • China Merchants Xinjiang Quality Inspection Technology Research Institute Co., Ltd, Xinjiang, PR China.
  • Xinjiang Uygur Autonomous Region Quality Basic Development Research Institute, Urumqi, Xinjiang, PR China.

Förderung

  • Xinjiang Uygur Autonomous Region Graduate Student Research and Innovation Program Grants
  • Natural Science Foundation of Xinjiang Uygur Autonomous Region

Zitieren

APA

Li, J., Long, Z., Li, X., Wang, J., Fan, T., & Wang, K. (2026). A dual-response ratiometric fluorescent probe based on Tb3+/Eu3+-functionalized MOF-membrane on silica microspheres: highly selective detection of cefixime and tetracyclines via a built-in self-calibration strategy. Microchimica Acta. https://doi.org/10.1007/s00604-026-08260-8

Vancouver

Li J, Long Z, Li X, Wang J, Fan T, Wang K. A dual-response ratiometric fluorescent probe based on Tb3+/Eu3+-functionalized MOF-membrane on silica microspheres: highly selective detection of cefixime and tetracyclines via a built-in self-calibration strategy. Microchimica Acta. 2026. doi:10.1007/s00604-026-08260-8

BibTeX
@article{Li2026,
  author = {Li, Junlong and Long, Zerong and Li, Xiaofei and Wang, Jianling and Fan, Tianli and Wang, Kai},
  title = {A dual-response ratiometric fluorescent probe based on Tb3+/Eu3+-functionalized MOF-membrane on silica microspheres: highly selective detection of cefixime and tetracyclines via a built-in self-calibration strategy},
  journal = {Microchimica Acta},
  year = {2026},
  doi = {10.1007/s00604-026-08260-8}
}
Kostenlos starten →