EUVIMEDEUVIMED entdecken
Crossref

Heterometallic Eu/Zn-MOF-based ratiometric sensing platform: Highly sensitive fluorescence / second-order scattering identification of tetracycline analogs and its molecular informatization applications

Ya Jie Fan, Jiang Xue Dong, Tan Liu, Yan Qing Chang, Yong Sen Zhao, Yan Lei Li, Sai Mei Zhang, Song Yun Cao, Ming Su, Shi Gang Shen, Zhong Feng Gao

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2024.342980 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Ya Jie Fan und 10 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding, 071002,…. Hauptthemen laut MEDLINE: Metal-Organic Frameworks, Europium, Zinc, Spectrometry, Fluorescence. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The traditional preparation method of ratiometric probes faces challenges such as cumbersome preparation and low sensitivity. Thus, there is an urgent need to provide a simple method of preparing a highly sensitive ratiometric probe. Here, Eu3+-doped zinc-based organic framework (Eu/Zn-MOF) was prepared through hydrothermal method for the detection of tetracycline analogs (TCs). Under the same excitation conditions, the probe can simultaneously display valuable fluorescence and second-order scattering signals. The developed probe enabled specific identification and fast detection (1 min) of TCs, including tetracycline, oxytetracycline, doxycycline, and chlortetracycline. The linear detection ranges of tetracycline, oxytetracycline, doxycycline and chlortetracycline were respectively 100 nM - 200 μM, 100 nM - 200 μM, 98 nM - 195 μM, and 97 nM - 291 μM, and the corresponding detection limits were respectively 15.79 nM, 20.83 nM, 15.31 nM, and 28.30 nM. The developed sensor was successfully applied to detect TCs in real samples, and the recovery rate was from 92.54 % to 109.69 % and the relative standard deviation was from 0.04 % to 2.97 %. Moreover, the heterometallic Eu/Zn-MOF was designed as a ratiometric neuron for Boolean logic computing and information encryption based on the specific identification of TCs. As a proof of concept, molecular steganography was successfully employed to encode, store, and conceal information by transforming the specific identification patterns of Eu/Zn-MOF into binary strings. This study is anticipated to advance the application of metal-organic frameworks in logic detection and information security, and bridging the gap between molecular sensors and the realm of information.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Metal-Organic FrameworksEuropiumZincSpectrometry, FluorescenceFluorescent DyesTetracyclinesLimit of DetectionAnti-Bacterial AgentsTetracyclineFluorescence

Stichwörter der Autor:innen

FluorescenceMolecular steganographyRatiometric sensorSecond-order scatteringTetracycline analogs

Substanzen

Metal-Organic FrameworksEuropiumZincFluorescent DyesTetracyclinesAnti-Bacterial AgentsTetracycline

Autor:innen und Institutionen

  • Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding, 071002, PR China.
  • Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding, 071002, PR China. Electronic address: dongjx@hbu.edu.cn.
  • Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
  • Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding, 071002, PR China. Electronic address: shensg@hbu.edu.cn.
  • Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China. Electronic address: chm_gaozf@ujn.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Fan, Y. J., Dong, J. X., Liu, T., Chang, Y. Q., Zhao, Y. S., Li, Y. L., Zhang, S. M., Cao, S. Y., Su, M., Shen, S. G., & Gao, Z. F. (2024). Heterometallic Eu/Zn-MOF-based ratiometric sensing platform: Highly sensitive fluorescence / second-order scattering identification of tetracycline analogs and its molecular informatization applications. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342980

Vancouver

Fan YJ, Dong JX, Liu T, Chang YQ, Zhao YS, Li YL, et al. Heterometallic Eu/Zn-MOF-based ratiometric sensing platform: Highly sensitive fluorescence / second-order scattering identification of tetracycline analogs and its molecular informatization applications. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342980

BibTeX
@article{Fan2024,
  author = {Fan, Ya Jie and Dong, Jiang Xue and Liu, Tan and Chang, Yan Qing and Zhao, Yong Sen and Li, Yan Lei and Zhang, Sai Mei and Cao, Song Yun and Su, Ming and Shen, Shi Gang and Gao, Zhong Feng},
  title = {Heterometallic Eu/Zn-MOF-based ratiometric sensing platform: Highly sensitive fluorescence / second-order scattering identification of tetracycline analogs and its molecular informatization applications},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2024.342980}
}
Kostenlos starten →