EUVIMEDEUVIMED entdecken
Crossref

Preparation and performance study of hydrogel microneedle sensors for in situ monitoring of potassium ions in rice plants

Jiuxiang Li, Jinhui Zhao, Junshi Huang, Muhua Liu, Shuanggen Huang

Microchimica Acta · 2026-02 · 193 (2)

DOI: 10.1007/s00604-026-07900-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 31.01.2026. Verfasst von Jiuxiang Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Jiangxi Key Laboratory of Modern Agricultural Equipment, Jiangxi Agricultural University, Nanchang, 330045, China. Hauptthemen laut MEDLINE: Oryza, Potassium, Biosensing Techniques, Hydrogels. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Science and Technology Research Project of the Jiangxi Provincial Department of Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To achieve real-time in situ monitoring of potassioum ions (K⁺) concentrations within plants and overcome the limitations of traditional destructive sampling methods, this study developed a microneedle (MN) biosensor featuring an ion-selective hydrogel at its tip. The sensor’s calibration curve and sensitivity were evaluated through in vitro electrochemical testing. Microforce testing and scanning electron microscopy were used to analyze the mechanical strength and microstructure of the MNs. Practical performance was validated through agarose gel recovery experiments and in vivo salt stress monitoring in rice via ion chromatography. The results indicate that the sensor exhibits near-Nernstian sensitivity toward K⁺ (59.3 ± 0.35 mV/decade), with a linear range from 0.1 mM to 100 mM and a detection limit of 3.5 × 10⁻³ mM. The sensor exhibited a rapid response (T95% = 15 ± 3 s), excellent stability, and high batch-to-batch reproducibility (RSD = 0.038%). The average breaking force of the MNs was 25.3 ± 2.1 mN, significantly exceeding the puncture threshold of the rice leaf epidermis (approximately 5–15 mN). In vivo experiments demonstrated that the sensor successfully monitored rapid K⁺ efflux dynamics in rice leaves under salt stress, and the results were highly consistent with those of ion chromatography (R² = 0.999). The hydrogel microneedle sensor developed in this study demonstrates reliable performance, providing a robust in situ analytical tool for investigating plant ion physiology and mechanisms of response to environmental stresses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OryzaPotassiumBiosensing TechniquesHydrogelsHydrogel, Polyethylene Glycol DimethacrylateNeedlesLimit of DetectionElectrochemical Techniques

Stichwörter der Autor:innen

Electrochemical sensingHydrogel microneedle sensorPotassium ionsPotentiometryReal-time in-situ detection

Substanzen

PotassiumHydrogelsHydrogel, Polyethylene Glycol Dimethacrylate

Autor:innen und Institutionen

  • Jiangxi Key Laboratory of Modern Agricultural Equipment, Jiangxi Agricultural University, Nanchang, 330045, China.
  • Jiangxi Biotech Vocational College, Nanchang, 330045, China.
  • Jiangxi Key Laboratory of Modern Agricultural Equipment, Jiangxi Agricultural University, Nanchang, 330045, China. zhaojh@jxau.edu.cn.

Förderung

  • Science and Technology Research Project of the Jiangxi Provincial Department of Education

Zitieren

APA

Li, J., Zhao, J., Huang, J., Liu, M., & Huang, S. (2026). Preparation and performance study of hydrogel microneedle sensors for in situ monitoring of potassium ions in rice plants. Microchimica Acta, 193(2). https://doi.org/10.1007/s00604-026-07900-3

Vancouver

Li J, Zhao J, Huang J, Liu M, Huang S. Preparation and performance study of hydrogel microneedle sensors for in situ monitoring of potassium ions in rice plants. Microchimica Acta. 2026;193(2). doi:10.1007/s00604-026-07900-3

BibTeX
@article{Li2026,
  author = {Li, Jiuxiang and Zhao, Jinhui and Huang, Junshi and Liu, Muhua and Huang, Shuanggen},
  title = {Preparation and performance study of hydrogel microneedle sensors for in situ monitoring of potassium ions in rice plants},
  journal = {Microchimica Acta},
  year = {2026},
  volume = {193},
  number = {2},
  doi = {10.1007/s00604-026-07900-3}
}
Kostenlos starten →