Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 17.05.2025. Verfasst von Daniela A Oliveira und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biological and Agricultural Engineering, Texas A&M University, College Station, TX, 77843, USA. Hauptthemen laut MEDLINE: Graphite, Nickel, Salmonella typhimurium, Electrochemical Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 85 Literaturangaben. Gefördert von: National Institute of Food and Agriculture.
Abstract (Originalsprache)
Cost-effectiveness, high-throughput capability, and scalable manufacturing are key features required for the fabrication of in-field electrochemical sensors applicable to food safety analysis. In this work, a two-step method is described to create laser-induced graphene electrodes decorated with nickel oxide nanoparticles (LIG-NiO). Fabrication of the LIG-NiO electrodes is performed via direct writing under ambient conditions using a polyimide sheet and nickel acetate solution as substrates, which is then converted into a label-free immunosensor for the detection of Salmonella enterica serovar Typhimurium by functionalizing the working surface with an anti-Salmonella antibody. The resulting electrochemical immunosensor exhibits a sensitivity of 3.93 ± 0.25 Ω (log (CFU mL-1)-1), a limit of detection (LOD) of 8 ± 3 CFU mL-1 and rapid response time (17 min) with a wide Salmonella Typhimurium linear sensing range, from 101 to 106 CFU mL-1 in buffer, covering relevant levels for food safety analysis without being affected by the presence of interferent bacteria Escherichia coli spp. Additionally, this LIG-NiO-based immunosensor presented a sensitivity of 1.92 ± 0.71 Ω (log (CFU mL-1)-1) when tested in chicken broth. The immunosensor developed in this study provides a simple fabrication method followed by functionalization and rapid Salmonella Typhimurium sensing that does not require sample pretreatment such as pre-enrichment or addition of external reagents, constituting a promising new sensing platform for pathogen detection in food safety monitoring and in general to other electrochemical immunosensing applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biological and Agricultural Engineering, Texas A&M University, College Station, TX, 77843, USA.
- Department of Food Science and Human Nutrition, Iowa State University, Ames, IA, 50011, USA.
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA.
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA.
- US Department of Energy, Ames National Laboratory, Ames, IA, 50011, USA.
- Department of Agricultural Sciences, Clemson University, Clemson, SC, 29631, USA.
ORCID-Profile: Cicero C Pola, Zachary T Johnson, Emily A Smith, Eric S McLamore, Diana C Vanegas, Jonathan C Claussen, Carmen L Gomes
Förderung
- National Institute of Food and Agriculture
Zitieren
APA
Oliveira, D. A., Pola, C. C., Johnson, Z. T., Li, J., Smith, E. A., McLamore, E. S., Vanegas, D. C., Claussen, J. C., & Gomes, C. L. (2025). Laser-induced graphene with nickel oxide nanoparticles electrochemical immunosensor for rapid and label-free detection of Salmonella enterica Typhimurium. Microchimica Acta, 192(6). https://doi.org/10.1007/s00604-025-07197-8
Vancouver
Oliveira DA, Pola CC, Johnson ZT, Li J, Smith EA, McLamore ES, et al. Laser-induced graphene with nickel oxide nanoparticles electrochemical immunosensor for rapid and label-free detection of Salmonella enterica Typhimurium. Microchimica Acta. 2025;192(6). doi:10.1007/s00604-025-07197-8
BibTeX
@article{Oliveira2025,
author = {Oliveira, Daniela A and Pola, Cicero C and Johnson, Zachary T and Li, Jingzhe and Smith, Emily A and McLamore, Eric S and Vanegas, Diana C and Claussen, Jonathan C and Gomes, Carmen L},
title = {Laser-induced graphene with nickel oxide nanoparticles electrochemical immunosensor for rapid and label-free detection of Salmonella enterica Typhimurium},
journal = {Microchimica Acta},
year = {2025},
volume = {192},
number = {6},
doi = {10.1007/s00604-025-07197-8}
}