A novel electrochemical sensor based on MIP technology for sensitive determination of cinacalcet hydrochloride in tablet dosage form and serum samples
Microchimica Acta · 2025
DOI: 10.1007/s00604-025-07152-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Ipek Kucuk und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, Faculty of Pharmacy, Başkent University, 06790, Ankara, Türkiye. Hauptthemen laut MEDLINE: Cinacalcet, Electrochemical Techniques, Molecularly Imprinted Polymers. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Social Science University of Ankara.
Abstract (Originalsprache)
Cinacalcet hydrochloride (CIN) is a calcium-sensing receptor agonist used to treat hypercalcemia in the parathyroid. The molecularly imprinted polymer (MIP)–based sensor (CIN@MIP/GCE) was electropolymerized using cyclic voltammetry (CV) of the functional monomer o-phenylenediamine (o–PD) with a template molecule CIN on a glassy carbon electrode (GCE). The optimum performance of the MIP-based electrode for CIN detection was obtained with parameters of a 1:7 monomer ratio, a 15-min removal time, ethanol as a removal solution, and a 15-min rebinding time. The surface characterization of the CIN@MIP/GCE sensor was conducted using atomic force microscopy (AFM) and scanning electron microscopy (SEM), while CV and electrochemical impedance spectroscopy (EIS) were employed for electrochemical characterization with [Fe(CN) 6 ] 3− / 4− redox probe. AFM findings show that the MIP sensor with CIN-specific voids on the surface has a root-mean-square (RMS) value of 27.95, while the non-imprinted polymer (NIP) sensor without voids has a smoother surface formation and an RMS value of 21.30 nm. The analytical efficacy of the constructed sensor was assessed using differential pulse voltammetry (DPV). The limit of detection (LOD) was 0.17 × 10 −12 , with a linear range of 1.0 × 10 −12 –1.0 × 10 −11 M. The reliability of the constructed sensor was determined using CIN detection in real samples as tablet dosage form and human serum, yielding recovery results of 100.19% and 101.82%, respectively. The selectivity investigation was performed against prevalent interference substances. The relative imprinting factor (IF) values of CIN impurities confirmed the selectivity of the CIN sensor. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Analytical Chemistry, Faculty of Pharmacy, Başkent University, 06790, Ankara, Türkiye.
- The Graduate School of Health Sciences, Ankara University, 06110, Ankara, Türkiye.
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara, Türkiye.
- NOBEL Holding A.S. R&D Center, 81100, Duzce, Türkiye.
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara, Türkiye. buslu@pharmacy.ankara.edu.tr.
Förderung
- Social Science University of Ankara
Zitieren
APA
Kucuk, I., Sadak, S., Kurnalı, S. Z., Altınöz, S., & Uslu, B. (2025). A novel electrochemical sensor based on MIP technology for sensitive determination of cinacalcet hydrochloride in tablet dosage form and serum samples. Microchimica Acta. https://doi.org/10.1007/s00604-025-07152-7
Vancouver
Kucuk I, Sadak S, Kurnalı SZ, Altınöz S, Uslu B. A novel electrochemical sensor based on MIP technology for sensitive determination of cinacalcet hydrochloride in tablet dosage form and serum samples. Microchimica Acta. 2025. doi:10.1007/s00604-025-07152-7
BibTeX
@article{Kucuk2025,
author = {Kucuk, Ipek and Sadak, Selenay and Kurnalı, Selda Zengin and Altınöz, Sacide and Uslu, Bengi},
title = {A novel electrochemical sensor based on MIP technology for sensitive determination of cinacalcet hydrochloride in tablet dosage form and serum samples},
journal = {Microchimica Acta},
year = {2025},
doi = {10.1007/s00604-025-07152-7}
}
EUVIMED